Mohr–Coulomb Strength Parameters from Two Triaxial Tests

Cohesion and friction angle from the confining pressure and deviator stress at failure of two triaxial tests, by the common tangent to their Mohr circles.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 100 and 300 kPa testsClean sand, no cohesionStiff clay, drained

Accepted: 0 to 5,000 kPa
Accepted: 0.001 to 10,000 kPa
Accepted: 0 to 5,000 kPa
Accepted: 0.001 to 10,000 kPa

Results

Each test gives a Mohr circle of centre σ₃ + q/2 and radius q/2; the common tangent τ = c + σtanφ satisfies r = c·cosφ + s·sinφ for both, so sinφ = Δr/Δs. Use effective stresses (subtract pore pressure) for drained parameters; more than two tests are better fitted by least squares on the p′–q plot. A negative cohesion means the envelope is curved over the stress range.

Friction angle23.765°
Cohesion intercept24.462kPa
Test 1 major principal stress310.00kPa
Failure plane angle from the major principal plane56.882°

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 100 and 300 kPa tests. The inputs, in the units selected above:

InputValue
Test 1 cell pressure100.00 kPa
Test 1 deviator stress at failure210.00 kPa
Test 2 cell pressure300.00 kPa
Test 2 deviator stress at failure480.00 kPa

Applying the formula below gives:

ResultValue
Friction angle23.765 °
Cohesion intercept24.462 kPa
Test 1 major principal stress310.00 kPa
Failure plane angle from the major principal plane56.882 °

Open this example in the calculator and change any input.

Formula

\(\sin\varphi = \frac{r_2 - r_1}{s_2 - s_1}, \quad c = \frac{r_1 - s_1\sin\varphi}{\cos\varphi}, \quad s = \sigma_3 + \frac q2, \ r = \frac q2\)

Variables

Symbol Meaning SI unit
\(\sigma_{3,1}\) Test 1 cell pressure Pa
\(q_1\) Test 1 deviator stress at failure Pa
\(\sigma_{3,2}\) Test 2 cell pressure Pa
\(q_2\) Test 2 deviator stress at failure Pa
\(\varphi\) Friction angle rad
\(c\) Cohesion intercept Pa
\(\sigma_{1,1}\) Test 1 major principal stress Pa
\(\theta_f\) Failure plane angle from the major principal plane rad

Method and standards

Strength fit.

Where it is used

  • Interpreting laboratory triaxial reports.
  • Strength parameters for slope and bearing analysis.

Common mistakes

  • Mixing total and effective stress tests.
  • Extrapolating far outside the tested stress range.

Assumptions and limits

  • Linear envelope between the tests.

References

  • Mohr–Coulomb failure criterion

Questions and answers

Why two tests?

Two Mohr circles define the straight envelope; real practice uses three or more and fits a line.

Total or effective stress?

Use effective stress for long-term (drained) analysis; total stress from undrained tests gives c_u and φ_u.

What do the defaults represent?

Two illustrative tests at 100 and 300 kPa cell pressure failing at deviator stresses of 210 and 480 kPa.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Das and Sobhan, Principles of Geotechnical Engineering, 8th ed. (Cengage, 2014), Craig, Craig's Soil Mechanics, 8th ed. (Spon, 2012)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.