Worked example
Example: Illustrative 8 m cut in sand. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Soil | Sand |
| Unit weight of the soil | 18.000 kN/m³ |
| Depth of the cut | 8.0000 m |
| Friction angle (sand) | 33.000 ° |
| Undrained shear strength (clay) | 40.000 kPa |
| Factor for stiff clay (0.2 to 0.4) | 0.30000 - |
| Horizontal strut spacing | 3.0000 m |
| Vertical height of wall carried by the strut | 2.5000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Active pressure coefficient (sand) | 0.29480 |
| Stability number γH/c_u (clay) | 3.6000 |
| Apparent pressure (uniform part of the envelope) | 27.593 kPa |
| Load on the strut | 206.95 kN |
Open this example in the calculator and change any input.
Formula
\(\text{sand: } p_a = 0.65K_a\gamma H, \quad \text{soft clay: } p_a = \gamma H\left(1 - \frac{4c_u}{\gamma H}\right) \ge 0.3\gamma H, \quad F = p_a s h_t\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{soil}\) | Soil | - |
| \(\gamma\) | Unit weight of the soil | N/m³ |
| \(H\) | Depth of the cut | m |
| \(\phi'\) | Friction angle (sand) | rad |
| \(c_u\) | Undrained shear strength (clay) | Pa |
| \(k\) | Factor for stiff clay (0.2 to 0.4) | - |
| \(s\) | Horizontal strut spacing | m |
| \(h_t\) | Vertical height of wall carried by the strut | m |
| \(K_a\) | Active pressure coefficient (sand) | - |
| \(N\) | Stability number γH/c_u (clay) | - |
| \(p_a\) | Apparent pressure (uniform part of the envelope) | Pa |
| \(F\) | Load on the strut | N |
Method and standards
Peck envelopes.
Where it is used
- Basement and trench shoring.
- Utility and metro excavations.
Common mistakes
- Applying the envelope to cantilever walls.
- Forgetting water pressure below the water table.
Assumptions and limits
- Cuts deeper than about 6 m; water table below the base or drained.
References
- Peck's apparent earth pressure envelopes for braced cuts
Questions and answers
Why not use Rankine pressure for struts?
Struts restrain the wall and arch the soil, so the loads differ from active pressure; Peck's envelopes come from measured strut loads.
What load does a strut carry?
The apparent pressure times its tributary area: spacing × the height of wall it supports.
What do the defaults represent?
An illustrative 8 m cut in sand (γ = 18 kN/m³, φ' = 33°) with struts 3 m apart supporting 2.5 m of wall each.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Peck, Deep excavations and tunnelling in soft ground, Proc. 7th ICSMFE (1969); Terzaghi, Peck and Mesri, Soil Mechanics in Engineering Practice, 3rd ed. (Wiley, 1996)