FireCADCalc

Allowable Bearing Pressure from SPT N (Meyerhof, Bowles)

Allowable bearing pressure of a shallow footing on sand for a chosen settlement from the corrected SPT N value, by Meyerhof's equations as modified by Bowles.

Inputs

Examples: Illustrative 2 m footing, N55 = 18Narrow 1 m footing, N55 = 12Wide 3 m footing, 40 mm allowed

Accepted: 1 to 100
Accepted: 0.3 to 20 m
Accepted: 0 to 10 m
Accepted: 5 to 100 mm

Results

Bowles' adjustment of Meyerhof (1965), N corrected to 55 % hammer energy, q_a in kPa for 25 mm settlement: q_a = (N/0.05)K_d for B ≤ 1.2 m and q_a = (N/0.08)[(B + 0.3)/B]²K_d for wider footings, K_d = 1 + 0.33D_f/B ≤ 1.33. Allowable pressure scales linearly with the tolerable settlement. The method is empirical for sands; check bearing capacity failure separately and reduce for a high water table.

Depth factor1.1980
Allowable bearing pressure356.48kPa
For 25 mm settlement356.48kPa
Load on a square footing1,425.9kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 2 m footing, N55 = 18. The inputs, in the units selected above:

InputValue
Corrected SPT N (55 % energy)18.000 -
Footing width2.0000 m
Footing depth1.2000 m
Tolerable settlement25.000 mm

Applying the formula below gives:

ResultValue
Depth factor1.1980
Allowable bearing pressure356.48 kPa
For 25 mm settlement356.48 kPa
Load on a square footing1,425.9 kN

Open this example in the calculator and change any input.

Formula

\(q_a = \frac{N_{55}}{F_2}\left(\frac{B + F_3}{B}\right)^2K_d\frac{S}{25\ \text{mm}}, \quad K_d = 1 + 0.33\frac{D_f}{B} \le 1.33\)

Variables

Symbol Meaning SI unit
\(N_{55}\) Corrected SPT N (55 % energy) -
\(B\) Footing width m
\(D_f\) Footing depth m
\(S\) Tolerable settlement m
\(K_d\) Depth factor -
\(q_a\) Allowable bearing pressure Pa
\(q_{a,25}\) For 25 mm settlement Pa
\(F\) Load on a square footing N

Method and standards

SPT bearing.

Where it is used

  • Preliminary footing sizing on sand.
  • Checking geotechnical report values.

Common mistakes

  • Using uncorrected field N.
  • Ignoring the water table.

Assumptions and limits

  • Sand; settlement-controlled; Bowles' F₂ = 0.05 and 0.08, F₃ = 0.3 m (SI).

References

  • Meyerhof's SPT method as modified by Bowles

Questions and answers

Why is allowable pressure settlement-based on sand?

Footings on sand usually reach tolerable settlement well before shear failure, so settlement governs.

Which N value should I use?

The corrected N₅₅ averaged over about one footing width below the base.

What do the defaults represent?

An illustrative 2 m square footing at 1.2 m depth on sand with corrected N₅₅ of 18 and 25 mm tolerable settlement.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Bowles, Foundation Analysis and Design, 5th ed. (McGraw-Hill, 1996), Das, Principles of Foundation Engineering, 7th ed. (Cengage, 2011)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.