Worked example
Example: Illustrative 180 kN/m wall on 150 kPa. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wall load per metre (service) | 180.00 kN/m |
| Footing self-weight allowance | 10.000 % |
| Allowable soil pressure | 150.00 kPa |
| Load factor | 1.5000 - |
| Wall thickness | 230.00 mm |
| Effective depth of footing | 250.00 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Footing width | 1.3200 m |
| Factored net upward pressure | 204.55 kPa |
| Cantilever projection | 0.54500 m |
| Factored moment at wall face per metre | 30.378 kN |
| Factored shear at d from wall face per metre | 60.341 kN/m |
Open this example in the calculator and change any input.
Formula
\(B = \frac{w(1 + f_{sw})}{q_a}, \quad q_u = \frac{\gamma_fw}{B}, \quad M_u = \frac{q_uc^2}{2}, \quad V_u = q_u(c - d)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(w\) | Wall load per metre (service) | N/m |
| \(f_{sw}\) | Footing self-weight allowance | - |
| \(q_a\) | Allowable soil pressure | Pa |
| \(\gamma_f\) | Load factor | - |
| \(t_w\) | Wall thickness | m |
| \(d\) | Effective depth of footing | m |
| \(B\) | Footing width | m |
| \(q_u\) | Factored net upward pressure | Pa |
| \(c\) | Cantilever projection | m |
| \(M_u\) | Factored moment at wall face per metre | N |
| \(V_u\) | Factored shear at d from wall face per metre | N/m |
Method and standards
Wall footing.
Where it is used
- Load-bearing masonry and retaining wall footings.
- Plant boundary and compound walls.
Common mistakes
- Including self-weight in the bending pressure.
- Taking the critical section at the wall centreline.
Assumptions and limits
- Concentric wall load; uniform pressure; one-way action.
References
- One-way cantilever action of wall footings
Questions and answers
Why does the footing's weight not count in bending?
Its weight is carried directly by the soil beneath it, so only the wall load produces net upward pressure that bends the slab.
Where is the critical section for moment?
At the face of a concrete wall; for masonry walls many codes use a section halfway between the wall's centre and its face.
What do the defaults represent?
An illustrative 180 kN/m wall load, 10 % self-weight allowance, 150 kPa allowable pressure, load factor 1.5, 230 mm wall and 250 mm effective depth.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Das, Principles of Foundation Engineering, 7th ed. (Cengage, 2011)