Strip Footing under a Wall: Width, Moment and Shear

Width of a wall strip footing from load per metre and allowable pressure, and the factored cantilever moment at the wall face and shear at a depth d from it.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 180 kN/m wall on 150 kPaLight 80 kN/m wall on 100 kPaHeavy 400 kN/m on 250 kPa

Accepted: 1 to 5,000 kN/m
Accepted: 0 to 30 %
Accepted: 10 to 2,000 kPa
Accepted: 1 to 2
Accepted: 100 to 1,500 mm
Accepted: 100 to 1,500 mm

Results

B = w(1 + f_sw)/q_a; the footing's own weight does not bend it, so design uses the net factored pressure q_u = γ_f·w/B. M_u = q_uc²/2 at the face of a concrete wall (masonry walls are often taken at a quarter of the wall thickness inside the face); V_u = q_u(c − d). Check depth and steel to the user's concrete code.

Footing width1.3200m
Factored net upward pressure204.55kPa
Cantilever projection0.54500m
Factored moment at wall face per metre30.378kN
Factored shear at d from wall face per metre60.341kN/m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 180 kN/m wall on 150 kPa. The inputs, in the units selected above:

InputValue
Wall load per metre (service)180.00 kN/m
Footing self-weight allowance10.000 %
Allowable soil pressure150.00 kPa
Load factor1.5000 -
Wall thickness230.00 mm
Effective depth of footing250.00 mm

Applying the formula below gives:

ResultValue
Footing width1.3200 m
Factored net upward pressure204.55 kPa
Cantilever projection0.54500 m
Factored moment at wall face per metre30.378 kN
Factored shear at d from wall face per metre60.341 kN/m

Open this example in the calculator and change any input.

Formula

\(B = \frac{w(1 + f_{sw})}{q_a}, \quad q_u = \frac{\gamma_fw}{B}, \quad M_u = \frac{q_uc^2}{2}, \quad V_u = q_u(c - d)\)

Variables

Symbol Meaning SI unit
\(w\) Wall load per metre (service) N/m
\(f_{sw}\) Footing self-weight allowance -
\(q_a\) Allowable soil pressure Pa
\(\gamma_f\) Load factor -
\(t_w\) Wall thickness m
\(d\) Effective depth of footing m
\(B\) Footing width m
\(q_u\) Factored net upward pressure Pa
\(c\) Cantilever projection m
\(M_u\) Factored moment at wall face per metre N
\(V_u\) Factored shear at d from wall face per metre N/m

Method and standards

Wall footing.

Where it is used

  • Load-bearing masonry and retaining wall footings.
  • Plant boundary and compound walls.

Common mistakes

  • Including self-weight in the bending pressure.
  • Taking the critical section at the wall centreline.

Assumptions and limits

  • Concentric wall load; uniform pressure; one-way action.

References

  • One-way cantilever action of wall footings

Questions and answers

Why does the footing's weight not count in bending?

Its weight is carried directly by the soil beneath it, so only the wall load produces net upward pressure that bends the slab.

Where is the critical section for moment?

At the face of a concrete wall; for masonry walls many codes use a section halfway between the wall's centre and its face.

What do the defaults represent?

An illustrative 180 kN/m wall load, 10 % self-weight allowance, 150 kPa allowable pressure, load factor 1.5, 230 mm wall and 250 mm effective depth.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Das, Principles of Foundation Engineering, 7th ed. (Cengage, 2011)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.