FireCADCalc

Negative Skin Friction (Downdrag) on a Pile

Drag load on a pile through a consolidating layer under fill by the effective-stress β method, and the allowable load left after subtracting downdrag.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 500 mm pile through 8 m clay600 mm pile, 12 m, heavy fillDriven 400 mm, water table drawdown

Accepted: 100 to 3,000 mm
Accepted: 0.5 to 60 m
Accepted: 0 to 500 kPa
Accepted: 2 to 15 kN/m³
Accepted: 0.05 to 1
Accepted: 10 to 100,000 kN
Accepted: 1 to 5

Results

Q_n = πD·β·∫σ'_v dz = πDβ(qH + γ'H²/2). β ≈ 0.2–0.3 for clay and silt, 0.3–0.5 for sand. This takes the whole layer as moving down relative to the pile; with a neutral plane inside the layer, only the part above it drags. A negative allowable load means downdrag alone exceeds the safe capacity.

Average vertical effective stress68.000kPa
Average negative skin friction17.000kPa
Drag load213.63kN
Allowable load after downdrag746.37kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 500 mm pile through 8 m clay. The inputs, in the units selected above:

InputValue
Pile diameter500.00 mm
Thickness of settling layer8.0000 m
Fill surcharge on top of the layer40.000 kPa
Effective unit weight of the layer7.0000 kN/m³
Shaft friction coefficient β0.25000 -
Ultimate pile capacity below the neutral plane2,400.0 kN
Factor of safety2.5000 -

Applying the formula below gives:

ResultValue
Average vertical effective stress68.000 kPa
Average negative skin friction17.000 kPa
Drag load213.63 kN
Allowable load after downdrag746.37 kN

Open this example in the calculator and change any input.

Formula

\(Q_n = \pi D\beta\left(qH + \frac{\gamma'H^2}{2}\right), \quad Q_a = \frac{Q_u}{FS} - Q_n\)

Variables

Symbol Meaning SI unit
\(D\) Pile diameter m
\(H\) Thickness of settling layer m
\(q\) Fill surcharge on top of the layer Pa
\(\gamma'\) Effective unit weight of the layer N/m³
\(\beta\) Shaft friction coefficient β -
\(Q_u\) Ultimate pile capacity below the neutral plane N
\(FS\) Factor of safety -
\(\bar\sigma'_v\) Average vertical effective stress Pa
\(f_n\) Average negative skin friction Pa
\(Q_n\) Drag load N
\(Q_a\) Allowable load after downdrag N

Method and standards

Downdrag.

Where it is used

  • Piles through reclaimed land and new fill.
  • Bridge abutment and tank piles.

Common mistakes

  • Using total stress for the friction.
  • Counting downdrag zone friction as positive capacity.

Assumptions and limits

  • Whole layer settles relative to the pile; uniform γ' and β.

References

  • Effective-stress (β) method for drag load
  • Fellenius
  • Basics of Foundation Design (electronic edition)

Questions and answers

What causes negative skin friction?

Soil settling more than the pile, typically soft clay under new fill or a lowered water table, hangs on the pile shaft.

Should drag load be added to the structural load?

For the pile's structural strength yes; for geotechnical capacity many designers instead check settlement at the neutral plane.

What do the defaults represent?

An illustrative 500 mm pile through 8 m of soft clay (γ' 7 kN/m³) under 40 kPa of fill, β 0.25, ultimate capacity 2,400 kN and FS 2.5.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Das, Principles of Foundation Engineering, 7th ed. (Cengage, 2011)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.