FireCADCalc

Block Machine Foundation: Vertical Natural Frequency and Amplitude

Vertical stiffness, natural frequency, damping ratio and steady vibration amplitude of a rigid block on an elastic half-space by Lysmer's analog.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 250 t block at 600 rpmCompressor 120 t at 300 rpmFan 60 t at 1480 rpm

Accepted: 0.5 to 50 m
Accepted: 0.5 to 50 m
Accepted: 0.1 to 100,000 t
Accepted: 1 to 10,000 MPa
Accepted: 0 to 0.49
Accepted: 1,000 to 2,500 kg/m³
Accepted: 0 to 10,000 kN
Accepted: 9.5493 to 3,819.7 rpm

Results

Lysmer's analog: k_z = 4Gr₀/(1 − ν), mass ratio B_z = (1 − ν)m/(4ρr₀³), D_z = 0.425/√B_z, A = (F₀/k_z)/√[(1 − r²)² + (2D_zr)²]. Common practice keeps the operating frequency at least 20–30 % away from resonance and amplitudes within the machine maker's limits. Use G at the small strains of machine vibration, not static values.

Equivalent radius2.7640m
Vertical stiffness990,073kN/m
Undamped natural frequency10.016Hz
Geometric damping ratio0.40490
Frequency ratio0.99843
Vertical amplitude24.984µm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 250 t block at 600 rpm. The inputs, in the units selected above:

InputValue
Block length6.0000 m
Block width4.0000 m
Mass of block and machine250.00 t
Soil shear modulus60.000 MPa
Soil Poisson's ratio0.33000 -
Soil density1,800.0 kg/m³
Unbalanced force amplitude20.000 kN
Operating speed600.00 rpm

Applying the formula below gives:

ResultValue
Equivalent radius2.7640 m
Vertical stiffness990,073 kN/m
Undamped natural frequency10.016 Hz
Geometric damping ratio0.40490
Frequency ratio0.99843
Vertical amplitude24.984 µm

Open this example in the calculator and change any input.

Formula

\(k_z = \frac{4Gr_0}{1 - \nu}, \quad B_z = \frac{(1 - \nu)m}{4\rho r_0^3}, \quad D_z = \frac{0.425}{\sqrt{B_z}}, \quad A_z = \frac{F_0/k_z}{\sqrt{(1 - r^2)^2 + (2D_zr)^2}}\)

Variables

Symbol Meaning SI unit
\(L\) Block length m
\(B\) Block width m
\(m\) Mass of block and machine kg
\(G\) Soil shear modulus Pa
\(\nu\) Soil Poisson's ratio -
\(\rho_s\) Soil density kg/m³
\(F_0\) Unbalanced force amplitude N
\(n\) Operating speed rad/s
\(r_0\) Equivalent radius m
\(k_z\) Vertical stiffness N/m
\(f_n\) Undamped natural frequency 1/s
\(D_z\) Geometric damping ratio -
\(r\) Frequency ratio -
\(A_z\) Vertical amplitude m

Method and standards

Block foundation.

Where it is used

  • Compressor, pump and fan foundations.
  • Turbine-generator and crusher pedestals.

Common mistakes

  • Using static soil modulus.
  • Ignoring embedment, which stiffens and damps the block.

Assumptions and limits

  • Rigid block on surface of elastic half-space; vertical mode only; constant force amplitude.

References

  • Lysmer's analog for vertical vibration

Questions and answers

Why is soil damping so high for vertical vibration?

Waves radiate energy into the half-space; vertical modes of heavy-footed blocks often have 20–50 % damping.

Where does G come from?

From shear wave velocity, G = ρV_s², measured by seismic tests at the site.

What do the defaults represent?

An illustrative 6 m × 4 m block of 250 t on soil with G 60 MPa, ν 0.33 and 1,800 kg/m³, with a 20 kN unbalanced force at 600 rpm.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Richart, Hall and Woods, Vibrations of Soils and Foundations (Prentice Hall, 1970)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.