Worked example
Example: Illustrative 2 x 3 m footing on sand. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Soil type for plate scaling | Sand (granular) |
| Plate (0.3 m) subgrade modulus | 40.000 MN/m³ |
| Footing width | 2.0000 m |
| Footing length | 3.0000 m |
| Soil elastic modulus | 30.000 MPa |
| Soil Poisson's ratio | 0.30000 - |
| Footing elastic modulus | 25.000 GPa |
| Footing thickness | 600.00 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Terzaghi scaled modulus | 13.225 MN/m³ |
| Vesić modulus | 10.167 MN/m³ |
| Vesić spring per unit length of beam | 20.335 MPa |
Open this example in the calculator and change any input.
Formula
\(k_{sand} = k_1\left(\frac{B + 0.3}{2B}\right)^2, \quad k_{clay} = k_1\frac{0.3}{B}\frac{L/B + 0.5}{1.5L/B}, \quad k_sB = 0.65\sqrt[12]{\frac{E_sB^4}{E_fI_f}}\frac{E_s}{1 - \nu^2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{soil}\) | Soil type for plate scaling | - |
| \(k_1\) | Plate (0.3 m) subgrade modulus | N/m³ |
| \(B\) | Footing width | m |
| \(L\) | Footing length | m |
| \(E_s\) | Soil elastic modulus | Pa |
| \(\nu\) | Soil Poisson's ratio | - |
| \(E_f\) | Footing elastic modulus | Pa |
| \(t\) | Footing thickness | m |
| \(k_T\) | Terzaghi scaled modulus | N/m³ |
| \(k_V\) | Vesić modulus | N/m³ |
| \(k_sB\) | Vesić spring per unit length of beam | Pa |
Method and standards
Subgrade modulus.
Where it is used
- Raft and grade beam analysis on springs.
- Machine and tank foundation models.
Common mistakes
- Using the plate value directly for a large raft.
- Treating k as a fixed soil constant.
Assumptions and limits
- Linear elastic soil; footing in full contact.
References
- Terzaghi plate scaling; Vesić beam-on-elastic-solid
Questions and answers
Why does k fall as footings get wider?
A wider footing stresses soil to a greater depth, so it settles more under the same pressure.
Which value should I use?
Both are estimates; run raft and beam analyses with a range, often half to twice the estimate.
What do the defaults represent?
An illustrative 2 m × 3 m, 600 mm concrete footing on sand with a plate test k₁ of 40 MN/m³ and E_s 30 MPa.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Terzaghi, Evaluation of coefficients of subgrade reaction, Géotechnique 5(4), 297 (1955), Vesić, Bending of beams resting on isotropic elastic solid, J. Eng. Mech. Div. ASCE 87(2), 35 (1961), Bowles, Foundation Analysis and Design, 5th ed. (McGraw-Hill, 1996)