Worked example
Example: Illustrative 500 mm pile through 8 m clay. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pile diameter | 500.00 mm |
| Thickness of settling layer | 8.0000 m |
| Fill surcharge on top of the layer | 40.000 kPa |
| Effective unit weight of the layer | 7.0000 kN/m³ |
| Shaft friction coefficient β | 0.25000 - |
| Ultimate pile capacity below the neutral plane | 2,400.0 kN |
| Factor of safety | 2.5000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Average vertical effective stress | 68.000 kPa |
| Average negative skin friction | 17.000 kPa |
| Drag load | 213.63 kN |
| Allowable load after downdrag | 746.37 kN |
Open this example in the calculator and change any input.
Formula
\(Q_n = \pi D\beta\left(qH + \frac{\gamma'H^2}{2}\right), \quad Q_a = \frac{Q_u}{FS} - Q_n\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Pile diameter | m |
| \(H\) | Thickness of settling layer | m |
| \(q\) | Fill surcharge on top of the layer | Pa |
| \(\gamma'\) | Effective unit weight of the layer | N/m³ |
| \(\beta\) | Shaft friction coefficient β | - |
| \(Q_u\) | Ultimate pile capacity below the neutral plane | N |
| \(FS\) | Factor of safety | - |
| \(\bar\sigma'_v\) | Average vertical effective stress | Pa |
| \(f_n\) | Average negative skin friction | Pa |
| \(Q_n\) | Drag load | N |
| \(Q_a\) | Allowable load after downdrag | N |
Method and standards
Downdrag.
Where it is used
- Piles through reclaimed land and new fill.
- Bridge abutment and tank piles.
Common mistakes
- Using total stress for the friction.
- Counting downdrag zone friction as positive capacity.
Assumptions and limits
- Whole layer settles relative to the pile; uniform γ' and β.
References
- Effective-stress (β) method for drag load
- Fellenius
- Basics of Foundation Design (electronic edition)
Questions and answers
What causes negative skin friction?
Soil settling more than the pile, typically soft clay under new fill or a lowered water table, hangs on the pile shaft.
Should drag load be added to the structural load?
For the pile's structural strength yes; for geotechnical capacity many designers instead check settlement at the neutral plane.
What do the defaults represent?
An illustrative 500 mm pile through 8 m of soft clay (γ' 7 kN/m³) under 40 kPa of fill, β 0.25, ultimate capacity 2,400 kN and FS 2.5.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Das, Principles of Foundation Engineering, 7th ed. (Cengage, 2011)