Worked example
Example: Illustrative 4 x 6 m group, 4 MN. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Total working load on the group | 4,000.0 kN |
| Group width (outer pile faces) | 4.0000 m |
| Group length (outer pile faces) | 6.0000 m |
| Pile length in the clay | 15.000 m |
| Compressible layer thickness below the raft | 10.000 m |
| Average effective unit weight | 9.0000 kN/m³ |
| Compression index | 0.30000 - |
| Initial void ratio | 0.90000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Depth of the equivalent raft | 10.000 m |
| Stress increase at mid-layer | 40.404 kPa |
| Effective overburden at mid-layer | 135.00 kPa |
| Consolidation settlement | 179.54 mm |
Open this example in the calculator and change any input.
Formula
\(z_r = \frac23L, \quad \Delta\sigma = \frac{Q_g}{(B_g + z)(L_g + z)}, \quad s_c = \frac{C_cH}{1 + e_0}\log\frac{\sigma_0' + \Delta\sigma}{\sigma_0'}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_g\) | Total working load on the group | N |
| \(B_g\) | Group width (outer pile faces) | m |
| \(L_g\) | Group length (outer pile faces) | m |
| \(L\) | Pile length in the clay | m |
| \(H\) | Compressible layer thickness below the raft | m |
| \(\gamma'\) | Average effective unit weight | N/m³ |
| \(C_c\) | Compression index | - |
| \(e_0\) | Initial void ratio | - |
| \(z_r\) | Depth of the equivalent raft | m |
| \(\Delta\sigma\) | Stress increase at mid-layer | Pa |
| \(\sigma_0'\) | Effective overburden at mid-layer | Pa |
| \(s_c\) | Consolidation settlement | m |
Method and standards
Group settlement.
Where it is used
- Settlement of piled foundations in clay.
- Comparing pile lengths for settlement.
Common mistakes
- Using single-pile settlement for a group.
- Ignoring layers below the raft.
Assumptions and limits
- Normally consolidated clay; single layer at mid-depth stress; uniform γ′.
References
- Equivalent raft (Terzaghi and Peck) with 2:1 spread
Questions and answers
Why two-thirds of the pile length?
Friction piles shed load along the shaft; a raft at two-thirds depth approximates where the group's load effectively enters the soil.
Is a single-layer calculation enough?
For thin layers yes; for thick or layered clays split into sub-layers and add the settlements.
What do the defaults represent?
An illustrative 4 × 6 m group carrying 4 MN with 15 m piles in clay, 10 m of compressible clay below the raft, γ′ 9 kN/m³, C_c 0.3, e₀ 0.9.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Terzaghi, Peck and Mesri, Soil Mechanics in Engineering Practice, 3rd ed. (Wiley, 1996), Das, Principles of Foundation Engineering, 7th ed. (Cengage, 2011)