Worked example
Example: Illustrative sand at 6 m, 0.24 g, M 7.5. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Depth of the layer | 6.0000 m |
| Water table depth | 2.0000 m |
| Unit weight above water table | 18.000 kN/m³ |
| Saturated unit weight | 19.500 kN/m³ |
| Peak ground acceleration | 0.24000 - |
| Earthquake moment magnitude | 7.5000 - |
| Clean-sand corrected SPT blow count | 14.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Total vertical stress | 114.00 kPa |
| Effective vertical stress | 74.760 kPa |
| Stress reduction factor | 0.95410 |
| Cyclic stress ratio | 0.22696 |
| Cyclic resistance ratio (M 7.5) | 0.15016 |
| Magnitude scaling factor | 0.99964 |
| Factor of safety against liquefaction | 0.66139 |
Open this example in the calculator and change any input.
Formula
\(CSR = 0.65\frac{a_{max}}{g}\frac{\sigma_v}{\sigma'_v}r_d, \quad CRR_{7.5} = \frac{1}{34 - N} + \frac{N}{135} + \frac{50}{(10N + 45)^2} - \frac{1}{200}, \quad FS = \frac{CRR\cdot MSF}{CSR}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(z\) | Depth of the layer | m |
| \(z_w\) | Water table depth | m |
| \(\gamma\) | Unit weight above water table | N/m³ |
| \(\gamma_{sat}\) | Saturated unit weight | N/m³ |
| \(a_{max}/g\) | Peak ground acceleration | - |
| \(M_w\) | Earthquake moment magnitude | - |
| \((N_1)_{60cs}\) | Clean-sand corrected SPT blow count | - |
| \(\sigma_v\) | Total vertical stress | Pa |
| \(\sigma'_v\) | Effective vertical stress | Pa |
| \(r_d\) | Stress reduction factor | - |
| \(CSR\) | Cyclic stress ratio | - |
| \(CRR_{7.5}\) | Cyclic resistance ratio (M 7.5) | - |
| \(MSF\) | Magnitude scaling factor | - |
| \(FS_L\) | Factor of safety against liquefaction | - |
Method and standards
Liquefaction screening.
Where it is used
- Site screening for plant and tank foundations.
- Deciding whether ground improvement is needed.
Common mistakes
- Using uncorrected field N values.
- Applying it to clays or gravelly soils.
Assumptions and limits
- Level ground; depth up to 23 m; (N₁)₆₀cs below 30.
Questions and answers
Which soils can liquefy?
Loose, saturated, clean to silty sands and non-plastic silts; dense or clayey soils generally do not.
Where does a_max come from?
From the site seismic hazard and site amplification, as specified by the user's seismic code or a site-specific study.
What do the defaults represent?
An illustrative sand layer at 6 m with the water table at 2 m, a_max 0.24g, magnitude 7.5 and (N₁)₆₀cs 14.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Simplified procedure (Seed–Idriss) with NCEER (2001) recommendations, Youd et al., Liquefaction resistance of soils: summary report from the 1996 NCEER and 1998 NCEER/NSF workshops, J. Geotech. Geoenviron. Eng. 127(10), 817 (2001)