FireCADCalc

Liquefaction Screening by the Simplified Procedure (SPT)

Cyclic stress ratio from peak ground acceleration and stresses, cyclic resistance ratio from clean-sand SPT blow count, magnitude scaling and factor of safety.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative sand at 6 m, 0.24 g, M 7.5Deeper layer at 12 m, M 6.5Loose shallow sand, M 8

Accepted: 0.5 to 23 m
Accepted: 0 to 23 m
Accepted: 12 to 23 kN/m³
Accepted: 14 to 24 kN/m³
Accepted: 0.01 to 1.5
Accepted: 5 to 9
Accepted: 1 to 29.9

Results

Seed–Idriss: CSR = 0.65(a_max/g)(σ_v/σ'_v)r_d with the Liao–Whitman r_d; CRR₇.₅ from the NCEER clean-sand curve fit; MSF = 10^2.24/M_w^2.56. FS below about 1.2–1.3 calls for detailed study. Fines and overburden (K_σ) corrections are assumed already applied to (N₁)₆₀cs or neglected. Soils with (N₁)₆₀cs ≥ 30 are taken as too dense to liquefy.

Total vertical stress234.00kPa
Effective vertical stress145.71kPa
Stress reduction factor0.85360
Cyclic stress ratio0.26731
Cyclic resistance ratio (M 7.5)0.21541
Magnitude scaling factor1.4419
Factor of safety against liquefaction1.1620

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative sand at 6 m, 0.24 g, M 7.5. The inputs, in the units selected above:

InputValue
Depth of the layer6.0000 m
Water table depth2.0000 m
Unit weight above water table18.000 kN/m³
Saturated unit weight19.500 kN/m³
Peak ground acceleration0.24000 -
Earthquake moment magnitude7.5000 -
Clean-sand corrected SPT blow count14.000 -

Applying the formula below gives:

ResultValue
Total vertical stress114.00 kPa
Effective vertical stress74.760 kPa
Stress reduction factor0.95410
Cyclic stress ratio0.22696
Cyclic resistance ratio (M 7.5)0.15016
Magnitude scaling factor0.99964
Factor of safety against liquefaction0.66139

Open this example in the calculator and change any input.

Formula

\(CSR = 0.65\frac{a_{max}}{g}\frac{\sigma_v}{\sigma'_v}r_d, \quad CRR_{7.5} = \frac{1}{34 - N} + \frac{N}{135} + \frac{50}{(10N + 45)^2} - \frac{1}{200}, \quad FS = \frac{CRR\cdot MSF}{CSR}\)

Variables

Symbol Meaning SI unit
\(z\) Depth of the layer m
\(z_w\) Water table depth m
\(\gamma\) Unit weight above water table N/m³
\(\gamma_{sat}\) Saturated unit weight N/m³
\(a_{max}/g\) Peak ground acceleration -
\(M_w\) Earthquake moment magnitude -
\((N_1)_{60cs}\) Clean-sand corrected SPT blow count -
\(\sigma_v\) Total vertical stress Pa
\(\sigma'_v\) Effective vertical stress Pa
\(r_d\) Stress reduction factor -
\(CSR\) Cyclic stress ratio -
\(CRR_{7.5}\) Cyclic resistance ratio (M 7.5) -
\(MSF\) Magnitude scaling factor -
\(FS_L\) Factor of safety against liquefaction -

Method and standards

Liquefaction screening.

Where it is used

  • Site screening for plant and tank foundations.
  • Deciding whether ground improvement is needed.

Common mistakes

  • Using uncorrected field N values.
  • Applying it to clays or gravelly soils.

Assumptions and limits

  • Level ground; depth up to 23 m; (N₁)₆₀cs below 30.

Questions and answers

Which soils can liquefy?

Loose, saturated, clean to silty sands and non-plastic silts; dense or clayey soils generally do not.

Where does a_max come from?

From the site seismic hazard and site amplification, as specified by the user's seismic code or a site-specific study.

What do the defaults represent?

An illustrative sand layer at 6 m with the water table at 2 m, a_max 0.24g, magnitude 7.5 and (N₁)₆₀cs 14.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Simplified procedure (Seed–Idriss) with NCEER (2001) recommendations, Youd et al., Liquefaction resistance of soils: summary report from the 1996 NCEER and 1998 NCEER/NSF workshops, J. Geotech. Geoenviron. Eng. 127(10), 817 (2001)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.