Worked example
Example: Illustrative drop hammer on a concrete pile. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Hammer (ram) weight | 40.000 kN |
| Drop of the hammer | 1.0000 m |
| Hammer efficiency | 80.000 % |
| Final set per blow | 2.5000 mm |
| Total temporary compression (pile, cap, soil) | 15.000 mm |
| Pile weight (with helmet) | 35.000 kN |
| Coefficient of restitution | 0.40000 - |
| Factor of safety | 2.5000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Ultimate driving resistance | 1,945.6 kN |
| Safe load | 778.24 kN |
| Efficiency of the blow | 60.800 % |
| Energy per blow at the pile | 19.456 kJ |
Open this example in the calculator and change any input.
Formula
\(R_u = \frac{\eta_hWh}{s + c/2}\cdot\frac{W + e_r^2P}{W + P}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W\) | Hammer (ram) weight | N |
| \(h\) | Drop of the hammer | m |
| \(\eta_h\) | Hammer efficiency | - |
| \(s\) | Final set per blow | m |
| \(c\) | Total temporary compression (pile, cap, soil) | m |
| \(P\) | Pile weight (with helmet) | N |
| \(e_r\) | Coefficient of restitution | - |
| \(F\) | Factor of safety | - |
| \(R_u\) | Ultimate driving resistance | N |
| \(R_a\) | Safe load | N |
| \(\eta_b\) | Efficiency of the blow | - |
| \(E\) | Energy per blow at the pile | J |
Method and standards
Hiley formula.
Where it is used
- Driving control of precast and steel piles.
- Setting the final set for a required capacity.
Common mistakes
- Using the set from a single blow.
- Applying it to piles in clay without tests.
Assumptions and limits
- Impact theory with restitution; sand or gravel ground; set from the final blows.
References
- Hiley pile-driving formula
Questions and answers
Why is the formula unreliable in clay?
Clays gain strength after driving (set-up) and resist differently under impact than under static load.
What restitution coefficient should I use?
About 0.5 for steel on steel without cushion, 0.4 for concrete piles with a helmet and packing, 0.25 for timber.
What do the defaults represent?
An illustrative 40 kN drop hammer falling 1 m at 80 % efficiency onto a 35 kN concrete pile, 2.5 mm set and 15 mm temporary compression.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Tomlinson and Woodward, Pile Design and Construction Practice, 6th ed. (CRC Press, 2014)