FireCADCalc

Isolated Footing Depth for One-Way and Punching Shear

Net soil pressure, effective depth for one-way and two-way (punching) shear, and bending moment at the column face of a square isolated footing.

Inputs

Examples: Illustrative 2.4 m footing, 1200 kN3.5 m footing, 3000 kNSmall 1.5 m footing, 450 kN

Accepted: 10 to 100,000 kN
Accepted: 0.5 to 10 m
Accepted: 100 to 2,000 mm
Accepted: 0.1 to 5 MPa
Accepted: 0.1 to 5 MPa

Results

One-way shear at d from the face: q(B − c − 2d)/2 = v_c1·d. Punching at d/2: q(B² − (c + d)²) = v_c2·4(c + d)d. Moment at the face q·B·x²/2 with x = (B − c)/2. Take allowable stresses from your code; overall depth adds cover and half a bar.

Net factored soil pressure200.00kPa
Depth for one-way shear133.33mm
Depth for punching shear167.24mm
Effective depth needed167.24mm
Moment at column face (whole width)54.000kN·m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 2.4 m footing, 1200 kN. The inputs, in the units selected above:

InputValue
Factored column load1,200.0 kN
Footing width (square)2.4000 m
Column width (square)400.00 mm
Allowable one-way shear stress0.75000 MPa
Allowable punching shear stress1.4000 MPa

Applying the formula below gives:

ResultValue
Net factored soil pressure208.33 kPa
Depth for one-way shear217.39 mm
Depth for punching shear286.57 mm
Effective depth needed286.57 mm
Moment at column face (whole width)250.00 kN·m

Open this example in the calculator and change any input.

Formula

\(q_u = \frac{P_u}{B^2}, \quad d_1 = \frac{q_u(B - c)/2}{v_{c1} + q_u}, \quad q_u\left[B^2 - (c + d)^2\right] = 4v_{c2}(c + d)d\)

Variables

Symbol Meaning SI unit
\(P_u\) Factored column load N
\(B\) Footing width (square) m
\(c\) Column width (square) m
\(v_{c1}\) Allowable one-way shear stress Pa
\(v_{c2}\) Allowable punching shear stress Pa
\(q_u\) Net factored soil pressure Pa
\(d_1\) Depth for one-way shear m
\(d_2\) Depth for punching shear m
\(d\) Effective depth needed m
\(M_u\) Moment at column face (whole width) N·m

Method and standards

Footing shear.

Where it is used

  • Isolated footing design.
  • Checking footings for added load.

Common mistakes

  • Using gross instead of net pressure.
  • Ignoring punching for thin footings.

Assumptions and limits

  • Concentric load; square footing and column; rigid footing.

References

  • Shear and flexure of square spread footings

Questions and answers

Which shear usually governs?

Punching for square footings under single columns; one-way shear for long narrow footings.

Why use net pressure?

The footing's own weight and the soil above it act straight down on the soil without causing shear or bending in the slab.

What do the defaults represent?

An illustrative 2.4 m square footing under a 400 mm column carrying a 1,200 kN factored load.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Bowles, Foundation Analysis and Design, 5th ed. (McGraw-Hill, 1996), ch. 8

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.