Worked example
Example: 20 t soybean oil IV 130 → 75. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Oil | 20,000 kg |
| Iodine value before | 130.00 - |
| Iodine value after | 75.000 - |
| Hydrogen losses (purge, dissolved) | 5.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hydrogen | 91.742 kg |
| Hydrogen volume at 0 °C, 1 atm | 1,020.0 m³ |
| Hydrogen per tonne of oil | 4.5871 kg/t |
Open this example in the calculator and change any input.
Formula
\(n = \frac{M(IV_1 - IV_2)}{100\,M_{I_2}}, \quad m_{H_2} = nM_{H_2}(1 + x)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(M\) | Oil | kg |
| \(IV_1\) | Iodine value before | - |
| \(IV_2\) | Iodine value after | - |
| \(x\) | Hydrogen losses (purge, dissolved) | - |
| \(m_{H_2}\) | Hydrogen | kg |
| \(V_{H_2}\) | Hydrogen volume at 0 °C, 1 atm | m³ |
| \(m_{H_2}/M\) | Hydrogen per tonne of oil | kg/kg |
Method and standards
Iodine value stoichiometry.
Where it is used
- Hydrogenation plant hydrogen budgets.
Common mistakes
- Using wrong IV units.
- Forgetting purge losses.
Assumptions and limits
- Ideal gas at 0 °C, 1 atm for volume.
References
- Definitions and mass and energy balances: iodine value = g I₂ per 100 g oil; one H₂ saturates the double bond that adds one I₂
Questions and answers
Where does 0.08 kg/t per IV come from?
1 g I₂ per 100 g oil = 10 kg I₂ per tonne; × 2.016/253.8 = 0.079 kg H₂.
Why add losses?
Purge, dissolved hydrogen and leaks; 5–10 % is usual.
Does IV fall linearly with hydrogen?
Yes, by definition; selectivity decides which fatty acids are saturated.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.