FireCADCalc

Space Velocity and Space Time of a Reactor

Space velocity (GHSV or LHSV) and space time of a catalytic or other reactor from the feed volumetric flow at reference conditions and the bed volume.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: SCR catalystIon-exchange bed

Gas at the standard conditions your industry uses (GHSV), or liquid at 15 °C (LHSV).

Results

Space time is not the true residence time unless the flow is at reactor conditions and the bed is empty volume.

Space velocity2,000.01/h
Space time V/V̇₀1.8000s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: SCR catalyst. The inputs, in the units selected above:

InputValue
Feed flow at reference conditions5,000.0 m³/h
Catalyst bed (or reactor) volume2.5000 m³

Applying the formula below gives:

ResultValue
Space velocity2,000.0 1/h
Space time V/V̇₀1.8000 s

Open this example in the calculator and change any input.

Formula

\(SV = \frac{\dot V_0}{V}, \quad \tau_s = \frac{V}{\dot V_0}\)

Variables

Symbol Meaning SI unit
\(\dot V_0\) Feed flow at reference conditions m³/s
\(V\) Catalyst bed (or reactor) volume m³
\(SV\) Space velocity 1/s
\(\tau_s\) Space time V/V̇₀ s

Method and standards

Definitions.

Where it is used

  • Catalytic reactors, SCR and hydrotreaters.
  • Ion exchange and adsorber beds (bed volumes per hour).

Common mistakes

  • Actual instead of reference flow.
  • Bed volume vs reactor volume.

Assumptions and limits

  • Uniform bed.
  • With zero flow the space time is unbounded and is not shown.

References

  • Definitions SV = V̇₀/V
  • τ = V/V̇₀ (Fogler)

Questions and answers

5000 m³/h through 2.5 m³ of catalyst?

GHSV 2000 /h, space time 1.8 s.

Why reference conditions?

So reactors at different pressures and temperatures compare.

SCR and deNOx catalysts?

Makers quote GHSV ranges for their catalyst.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.