FireCADCalc

Residence Time Distribution: Tanks-in-Series Number and Conversion

Equivalent number of tanks in series from the mean and variance of a tracer residence time distribution, and the first-order conversion it predicts.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 10 min mean, 3.3 min SDHolding tube, narrow RTD

Results

N from the variance: σ²/t_m² = 1/N. For large N the dispersion model gives about the same with Pe ≈ 2N.

Equivalent tanks in series100.00
First-order conversion with N tanks77.437%
Conversion in plug flow77.687%
Equivalent axial Péclet number (closed vessel, large Pe)200.00

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 min mean, 3.3 min SD. The inputs, in the units selected above:

InputValue
Mean residence time10.000 min
Standard deviation of the RTD3.3333 min
First-order rate constant0.004000 1/min

Applying the formula below gives:

ResultValue
Equivalent tanks in series9.0000
First-order conversion with N tanks3.9125 %
Conversion in plug flow3.9211 %
Equivalent axial Péclet number (closed vessel, large Pe)18.000

Open this example in the calculator and change any input.

Formula

\(N = \frac{t_m^2}{\sigma^2}, \quad X_N = 1 - \left(1 + \frac{kt_m}{N}\right)^{-N}\)

Variables

Symbol Meaning SI unit
\(t_m\) Mean residence time s
\(\sigma\) Standard deviation of the RTD s
\(k\) First-order rate constant 1/s
\(N\) Equivalent tanks in series -
\(X_N\) First-order conversion with N tanks -
\(X_{PFR}\) Conversion in plug flow -
\(Pe\) Equivalent axial Péclet number (closed vessel, large Pe) -

Method and standards

Tanks-in-series model.

Where it is used

  • Reactor troubleshooting from tracer tests.
  • Holding tube and pasteuriser checks.

Common mistakes

  • Using RTD data with a tail cut off.
  • Applying it to non-first-order reactions with segregation.

Assumptions and limits

  • First order; N from variance.
  • N below 1 (a spread wider than one stirred tank) is outside the model and is flagged; Pe ≈ 2N is flagged as rough for N below 5.

References

  • Levenspiel
  • Chemical Reaction Engineering
  • 3rd ed. (Wiley, 1999)
  • ch. 14 (tanks-in-series model)

Questions and answers

How do I get the variance?

From a tracer test: σ² = Σ(t − t_m)²C Δt / Σ C Δt.

What does N tell me?

N = 1 is a fully mixed tank; large N approaches plug flow. Holding tubes and long pipes reach N of 20–100.

What do the defaults represent?

A vessel with a 10 min mean residence time and a 3.3 min standard deviation.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.