FireCADCalc

Plug-Flow Reactor with Recycle: Conversion

Conversion of a first-order reaction in a plug-flow reactor with product recycle, from rate constant, space time and recycle ratio, against PFR and CSTR.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: kτ = 2, R = 2High recycle R = 20

Results

Constant density, isothermal. Recycle is used for autocatalytic reactions or to limit temperature rise; for simple positive-order reactions it lowers conversion.

Conversion with recycle73.980%
Without recycle86.466%
Fully mixed limit66.667%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: kτ = 2, R = 2. The inputs, in the units selected above:

InputValue
First-order rate constant0.010000 Hz
Space time V/v₀ (fresh feed basis)200.00 s
Recycle ratio (recycled/fresh)2.0000 -

Applying the formula below gives:

ResultValue
Conversion with recycle73.980 %
Without recycle86.466 %
Fully mixed limit66.667 %

Open this example in the calculator and change any input.

Formula

\(k\tau = (R + 1)\ln\frac{1 + R(1 - X)}{(R + 1)(1 - X)}\)

Variables

Symbol Meaning SI unit
\(k\) First-order rate constant 1/s
\(\tau\) Space time V/v₀ (fresh feed basis) s
\(R\) Recycle ratio (recycled/fresh) -
\(X\) Conversion with recycle -
\(X_{PFR}\) Without recycle -
\(X_{CSTR}\) Fully mixed limit -

Method and standards

Levenspiel's recycle reactor.

Where it is used

  • Loop reactors.
  • Exothermic reactors with product recycle.

Common mistakes

  • Basing τ on total (fresh + recycle) flow.
  • Using it for non-isothermal operation.

Assumptions and limits

  • First order; constant density.

References

  • Levenspiel
  • Chemical Reaction Engineering
  • 3rd ed. (Wiley, 1999)
  • ch. 6 (recycle reactor: kτ = (R + 1) ln[(1 + R(1 − X))/((R + 1)(1 − X))])

Questions and answers

Why would anyone recycle in a PFR?

For autocatalytic reactions, to dilute a very exothermic feed, or to keep catalyst wetted; the conversion per pass then lies between PFR and CSTR.

What happens at very high recycle?

The reactor behaves as a CSTR.

What do the defaults represent?

A first-order reaction with kτ = 2 and twice as much recycle as fresh feed.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators