Worked example
Example: kτ = 2, R = 2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| First-order rate constant | 0.010000 Hz |
| Space time V/v₀ (fresh feed basis) | 200.00 s |
| Recycle ratio (recycled/fresh) | 2.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Conversion with recycle | 73.980 % |
| Without recycle | 86.466 % |
| Fully mixed limit | 66.667 % |
Open this example in the calculator and change any input.
Formula
\(k\tau = (R + 1)\ln\frac{1 + R(1 - X)}{(R + 1)(1 - X)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(k\) | First-order rate constant | 1/s |
| \(\tau\) | Space time V/v₀ (fresh feed basis) | s |
| \(R\) | Recycle ratio (recycled/fresh) | - |
| \(X\) | Conversion with recycle | - |
| \(X_{PFR}\) | Without recycle | - |
| \(X_{CSTR}\) | Fully mixed limit | - |
Method and standards
Levenspiel's recycle reactor.
Where it is used
- Loop reactors.
- Exothermic reactors with product recycle.
Common mistakes
- Basing τ on total (fresh + recycle) flow.
- Using it for non-isothermal operation.
Assumptions and limits
- First order; constant density.
References
- Levenspiel
- Chemical Reaction Engineering
- 3rd ed. (Wiley, 1999)
- ch. 6 (recycle reactor: kτ = (R + 1) ln[(1 + R(1 − X))/((R + 1)(1 − X))])
Questions and answers
Why would anyone recycle in a PFR?
For autocatalytic reactions, to dilute a very exothermic feed, or to keep catalyst wetted; the conversion per pass then lies between PFR and CSTR.
What happens at very high recycle?
The reactor behaves as a CSTR.
What do the defaults represent?
A first-order reaction with kτ = 2 and twice as much recycle as fresh feed.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.