Worked example
Example: Three tanks, k tau = 3. The inputs, in the units selected above:
| Input | Value |
|---|---|
| First-order rate constant | 0.10000 1/min |
| Total residence time | 30.000 min |
| Number of equal tanks | 3.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Conversion with N tanks | 87.500 % |
| One tank of the same total volume | 75.000 % |
| Plug flow reactor | 95.021 % |
Open this example in the calculator and change any input.
Formula
\(X_N = 1 - \left(1 + \frac{k\tau}{N}\right)^{-N}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(k\) | First-order rate constant | 1/s |
| \(\tau\) | Total residence time | s |
| \(N\) | Number of equal tanks | - |
| \(X_N\) | Conversion with N tanks | - |
| \(X_1\) | One tank of the same total volume | - |
| \(X_{PFR}\) | Plug flow reactor | - |
Method and standards
Tanks-in-series.
Where it is used
- Effluent neutralisation and reactor cascades.
- Choosing tank numbers.
Common mistakes
- Using each tank's τ as the total.
- Unequal tanks in the formula.
Assumptions and limits
- Equal tanks, first order.
References
- Tanks-in-series
- first order: X = 1 − (1 + kτ/N)^(−N) (Levenspiel)
Questions and answers
k 0.1 /min, 30 min, three tanks?
0.875 against 0.75 for one tank and 0.950 plug flow.
Why do more tanks help?
Each runs at a higher concentration than one big tank.
Neutralisation cascades?
The same reasoning sets how many stages are worth it.