FireCADCalc

Batch Reactor: Peak Heat Release and Cooling Area

Peak heat release of a first-order exothermic batch reaction at the start of the batch, the cooling area needed to hold temperature, and the heat released by a time.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 10 m³, 2 kmol/m³, k 1/h, 100 kJ/molFast nitration-like 2 m³

Results

Isothermal operation with all reactant charged at the start: the cooling must match the initial peak. Semi-batch feeding spreads the load. Check the adiabatic temperature rise for runaway risk.

Peak heat release (at t = 0)2,000.0kW
Cooling area needed133.33m²
Heat release at time t446.26kW
Heat released up to t258.96kWh
Conversion at t77.687%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 m³, 2 kmol/m³, k 1/h, 100 kJ/mol. The inputs, in the units selected above:

InputValue
Reacting volume10.000 m³
Initial concentration, in kmol/m³ (= mol/L; not mol/m³)2.0000 -
First-order rate constant at the operating temperature1.0000 1/h
Heat of reaction (released)100.00 kJ/mol
Overall coefficient400.00 W/(m²·K)
Reaction temperature80.000 °C
Mean coolant temperature30.000 °C
Time into the batch1.0000 h

Applying the formula below gives:

ResultValue
Peak heat release (at t = 0)555.56 kW
Cooling area needed27.778 m²
Heat release at time t204.38 kW
Heat released up to t351.18 kWh
Conversion at t63.212 %

Open this example in the calculator and change any input.

Formula

\(Q_0 = (-\Delta H_r)kC_{A0}V, \quad A = \frac{Q_0}{U(T_r - T_c)}, \quad Q(t) = Q_0e^{-kt}, \quad X = 1 - e^{-kt}\)

Variables

Symbol Meaning SI unit
\(V\) Reacting volume m³
\(C_{A0}\) Initial concentration, in kmol/m³ (= mol/L; not mol/m³) kmol/m³
\(k\) First-order rate constant at the operating temperature 1/s
\(-\Delta H_r\) Heat of reaction (released) J/mol
\(U\) Overall coefficient W/(m²·K)
\(T_r\) Reaction temperature K
\(T_c\) Mean coolant temperature K
\(t\) Time into the batch s
\(Q_0\) Peak heat release (at t = 0) W
\(A\) Cooling area needed m²
\(Q(t)\) Heat release at time t W
\(E(t)\) Heat released up to t J
\(X(t)\) Conversion at t -

Method and standards

First-order heat release.

Where it is used

  • Jacket and coil sizing.
  • Safety review of batch charges.

Common mistakes

  • Sizing on the average duty.
  • Ignoring the rise of k with temperature.

Assumptions and limits

  • Isothermal; first order; all charged at start; the reactor is held at T_r (no heat accumulation).
  • The concentration is entered as a number in kmol/m³ (the same number as mol/L); a value in mol/m³ would be 1000 times too large.

References

  • Batch reactor energy balance for first-order kinetics (Levenspiel, Chemical Reaction Engineering, 3rd ed. (Wiley, 1999), ch. 9; Fogler, ch. 13)

Questions and answers

Why is the peak at the start?

With all reactant charged, the first-order rate is highest when concentration is highest.

How can the peak be cut?

Feed one reactant gradually (semi-batch), start colder, or dilute.

What do the defaults represent?

10 m³ at 2 kmol/m³ with a one-hour time constant and 100 kJ/mol released.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.