Worked example
Example: P/V constant. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Small impeller diameter | 0.15000 m |
| Small impeller speed | 300.00 rpm |
| Small agitator power | 0.050000 kW |
| Large impeller diameter | 0.90000 m |
| Scale-up rule | Constant power per volume (N ∝ D^−2/3) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Large impeller speed | 90.856 rpm |
| Large agitator power | 10.800 kW |
| Power per volume ratio | 1.00000 |
Open this example in the calculator and change any input.
Formula
\(N_2 = N_1\left(\frac{D_1}{D_2}\right)^{2/3} \ \text{or} \ N_1\frac{D_1}{D_2}, \quad P_2 = P_1\left(\frac{N_2}{N_1}\right)^3\left(\frac{D_2}{D_1}\right)^5\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D_1\) | Small impeller diameter | m |
| \(N_1\) | Small impeller speed | 1/s |
| \(P_1\) | Small agitator power | W |
| \(D_2\) | Large impeller diameter | m |
| \(\text{rule}\) | Scale-up rule | - |
| \(N_2\) | Large impeller speed | 1/s |
| \(P_2\) | Large agitator power | W |
| \(\frac{P_2/V_2}{P_1/V_1}\) | Power per volume ratio | - |
Method and standards
Geometric similarity with a constant power number in turbulent flow, so P ∝ N³D⁵ and V ∝ D³; the speed follows from the chosen rule (constant P/V gives N ∝ D−2/3, constant tip speed N ∝ D−1).
Where it is used
- Pilot to plant agitators.
- Tank replacement.
Common mistakes
- Non-similar geometry.
- Laminar mixing.
Assumptions and limits
- Turbulent, geometrically similar.
References
- Turbulent agitation P = N_p ρN³D⁵ with geometric similarity (McCabe, Smith and Harriott)
Questions and answers
150 mm at 300 rpm, 50 W, to 900 mm by P/V?
91 rpm and 10.8 kW.
By tip speed?
50 rpm and 1.8 kW: less power per volume.
Which rule?
P/V for mass transfer and suspension; tip speed for shear-sensitive products.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.