FireCADCalc

Stirred Tank: Impeller Reynolds Number, Tip Speed and Froude Number

Impeller Reynolds number, tip speed and Froude number of a stirred tank from impeller diameter, speed and liquid properties, with the flow regime.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: 50 mPa·s liquid, just turbulent (Re 15 120)Turbulent waterLaminar paste

Results

Regime bands: laminar below about 10, turbulent above about 10⁴ (common practice).

Impeller Reynolds number ρND²/μ6.0000
Tip speed πND1.5708m/s
Froude number N²D/g0.025493
Regime (1 laminar, 2 transitional, 3 turbulent)1.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 mPa·s liquid, just turbulent (Re 15 120). The inputs, in the units selected above:

InputValue
Impeller diameter0.60000 m
Speed120.00 rpm
Liquid density1,050.0 kg/m³
Liquid viscosity0.050000 Pa·s

Applying the formula below gives:

ResultValue
Impeller Reynolds number ρND²/μ15,120
Tip speed πND3.7699 m/s
Froude number N²D/g0.24473
Regime (1 laminar, 2 transitional, 3 turbulent)3.0000

Open this example in the calculator and change any input.

Formula

\(Re = \frac{\rho N D^2}{\mu}, \quad v_t = \pi N D, \quad Fr = \frac{N^2 D}{g}\)

Variables

Symbol Meaning SI unit
\(D\) Impeller diameter m
\(N\) Speed 1/s
\(\rho\) Liquid density kg/m³
\(\mu\) Liquid viscosity Pa·s
\(Re\) Impeller Reynolds number ρND²/μ -
\(v_t\) Tip speed πND m/s
\(Fr\) Froude number N²D/g -
\(\text{regime}\) Regime (1 laminar, 2 transitional, 3 turbulent) -

Method and standards

Definitions.

Where it is used

  • Agitator selection and checks.
  • Lime and chemical preparation tanks.

Common mistakes

  • rpm not converted to rev/s.
  • Tank diameter for impeller diameter.

Assumptions and limits

  • Newtonian liquid.

References

  • Impeller Reynolds number Re = ρND²/μ (McCabe, Smith and Harriott; Paul, Atiemo-Obeng and Kresta)

Questions and answers

600 mm impeller at 120 rpm in 50 mPa·s liquid?

Re 15,120, just above the 10⁴ turbulent band used here (close to transitional in practice); tip speed 3.77 m/s.

Why does regime matter?

The power number is constant only in the turbulent range.

Tip speed?

A guide to shear and blending intensity.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.