Worked example
Example: Rushton turbine Np 5, 120 rpm, 0.6 m, water. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Power number of the impeller | 5.0000 - |
| Impeller speed | 120.00 rpm |
| Impeller diameter | 0.60000 m |
| Liquid density | 1,000.0 kg/m³ |
| Liquid viscosity | 1.0000 cP |
| Tank diameter | 1.8000 m |
| Liquid height | 1.8000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Impeller Reynolds number | 720,000 |
| Shaft power | 3.1104 kW |
| Shaft torque | 247.52 N·m |
| Tip speed | 3.7699 m/s |
| Liquid volume | 4.5804 m³ |
| Power per unit volume | 0.67906 kW/m³ |
Open this example in the calculator and change any input.
Formula
\(Re = \frac{\rho N D^2}{\mu}, \quad P = N_p \rho N^3 D^5\)
\(M = \frac{P}{2\pi N}, \quad u_{tip} = \pi N D, \quad V = \frac{\pi T^2}{4} H\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(N_p\) | Power number of the impeller | - |
| \(N\) | Impeller speed | 1/s |
| \(D\) | Impeller diameter | m |
| \(\rho\) | Liquid density | kg/m³ |
| \(\mu\) | Liquid viscosity | Pa·s |
| \(T\) | Tank diameter | m |
| \(H\) | Liquid height | m |
| \(Re\) | Impeller Reynolds number | - |
| \(P\) | Shaft power | W |
| \(M\) | Shaft torque | N·m |
| \(u_{tip}\) | Tip speed | m/s |
| \(V\) | Liquid volume | m³ |
| \(P/V\) | Power per unit volume | W/m³ |
Method and standards
The power number collects the impeller geometry; in the turbulent range it is constant, so power varies with ρN³D⁵.
Where it is used
- Sizing agitator motors and gearboxes.
- Scaling up mixing from a pilot vessel.
- Checking whether a mixer is loaded as expected.
Common mistakes
- Using the turbulent power number at low Reynolds numbers.
- Forgetting gassed power is lower and ungassed higher.
- Sizing the motor without drive losses.
Assumptions and limits
- Single impeller; baffled tank for the quoted power numbers. Unbaffled tanks (vortexing, Froude-number dependence) and multiple impellers on one shaft are outside scope: the power number entered must already account for them.
References
- Rushton
- Costich and Everett (1950)
- power characteristics of mixing impellers
Questions and answers
What power does a 0.6 m Rushton turbine take at 120 rpm in water?
With N_p 5, 3.1 kW at the shaft; Reynolds number 720 000, fully turbulent.
Why does power rise so fast with size?
P goes with N³D⁵: doubling the diameter at the same speed needs 32 times the power.
What power per volume is typical?
About 0.1 kW/m³ for gentle blending up to 1–2 kW/m³ for dispersion; the example gives 0.68 kW/m³.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.