Worked example
Example: Exothermic liquid reaction. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heat of reaction (negative: exothermic) | -80.000 kJ/mol |
| Feed concentration of the key reactant | 2.0000 mol/L |
| Conversion | 90.000 % |
| Mixture density | 950.00 kg/m³ |
| Mixture specific heat | 2.4000 kJ/(kg·K) |
| Feed temperature | 50.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Adiabatic temperature rise | 63.158 K |
| Outlet temperature (adiabatic) | 113.16 °C |
| Rise at full conversion | 70.175 K |
Open this example in the calculator and change any input.
Formula
\(\Delta T_{ad} = \frac{(-\Delta H_r) C_{A0} X}{\rho c_p}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\Delta H_r\) | Heat of reaction (negative: exothermic) | J/mol |
| \(C_{A0}\) | Feed concentration of the key reactant | mol/m³ |
| \(X\) | Conversion | - |
| \(\rho\) | Mixture density | kg/m³ |
| \(c_p\) | Mixture specific heat | J/(kg·K) |
| \(T_0\) | Feed temperature | K |
| \(\Delta T_{ad}\) | Adiabatic temperature rise | K |
| \(T\) | Outlet temperature (adiabatic) | K |
| \(\Delta T_{ad,100}\) | Rise at full conversion | K |
Method and standards
Energy balance.
Where it is used
- Reactor safety studies.
- Batch reactor design.
Common mistakes
- Concentration in mol/L used as mol/m³.
- Sign of ΔH.
Assumptions and limits
- Constant properties, no heat loss.
- Screening energy balance: no heat of mixing, no vaporisation or vapour pressure, no decomposition onset. Not a design basis for relief sizing (use calorimetry data and a recognised relief method).
- An endothermic reaction (ΔH_r > 0) gives a fall; a fall that would take the mixture below 0 K is rejected.
References
- Energy balance ΔT_ad = (−ΔH_r) C_A0 X/(ρ c_p) (Fogler; Stoessel, Thermal Safety of Chemical Processes)
Questions and answers
−80 kJ/mol at 2 mol/L, 90 % conversion?
About 63 K rise; 70 K at full conversion.
Why does it matter?
It is how hot the batch gets if cooling fails.
Gas-phase reactions?
Use the molar heat capacity of the gas mixture instead.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.