Joule–Thomson Temperature Change on Throttling (Peng–Robinson)

Temperature after throttling a real gas at constant enthalpy using the Peng–Robinson departure function and ideal-gas heat capacity, with the JT coefficient.

Thermal power plantDistillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Methane 70 → 10 bar at 27 °CCO2 40 → 10 bar at 50 °C

Per mole: multiply a value in J/(kg·K) by the molar mass in kg/mol.

Results

Vapour-root Peng–Robinson with constant ideal-gas C_p°; do not use if the throttled stream condenses. Natural gas cools about 0.4–0.5 K per bar near ambient.

Downstream temperature-2.3657°C
Temperature change-29.216K
Mean Joule–Thomson coefficient (K/bar)0.48693

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Methane 70 → 10 bar at 27 °C. The inputs, in the units selected above:

InputValue
Upstream temperature26.850 °C
Upstream pressure (absolute)70.000 bar
Downstream pressure (absolute)10.000 bar
Critical temperature-82.590 °C
Critical pressure45.990 bar
Acentric factor0.011400 -
Ideal-gas heat capacity (J/(mol·K))35.700 -

Applying the formula below gives:

ResultValue
Downstream temperature-2.3657 °C
Temperature change-29.216 K
Mean Joule–Thomson coefficient (K/bar)0.48693

Open this example in the calculator and change any input.

Formula

\(h(T_1, p_1) = h(T_2, p_2), \quad h - h^{ig} = RT(Z - 1) + \frac{T\,da/dT - a}{2\sqrt2b}\ln\frac{Z + (1 + \sqrt2)B}{Z + (1 - \sqrt2)B}\)

Variables

Symbol Meaning SI unit
\(T_1\) Upstream temperature K
\(p_1\) Upstream pressure Pa
\(p_2\) Downstream pressure Pa
\(T_c\) Critical temperature K
\(p_c\) Critical pressure Pa
\(\omega\) Acentric factor -
\(C_p^\circ\) Ideal-gas heat capacity (J/(mol·K)) -
\(T_2\) Downstream temperature K
\(\Delta T\) Temperature change K
\(\mu_{JT}\) Mean Joule–Thomson coefficient (K/bar) -

Method and standards

Peng–Robinson departure function.

Where it is used

  • Gas pressure-reducing stations.
  • Relief and vent temperature checks.

Common mistakes

  • Ignoring condensation.
  • Using C_p at another temperature.

Assumptions and limits

  • Pure gas; vapour root; constant C_p°, per mole in J/(mol·K). Pressures are absolute.
  • The vapour root is taken from the analytic solution of the cubic. The calculation stops if the downstream temperature falls outside 0.3–1.2 times the upstream temperature, if the enthalpy balance does not close, or if the liquid is the stable phase downstream (condensation).

References

  • Isenthalpic expansion with Peng–Robinson enthalpy departure (Perry's Chemical Engineers' Handbook, 9th ed. (McGraw-Hill, 2019), sec. 2 and 4)

Questions and answers

Why does gas cool on throttling?

Molecules attract each other; expanding them apart takes energy from the gas itself, at constant enthalpy.

Why does this matter?

At gas pressure-reducing stations the cooling can form hydrates or freeze the valve; gas is often preheated.

What do the defaults represent?

Methane let down from 70 to 10 bar at 27 °C.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.