Worked example
Example: Methane 70 → 10 bar at 27 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Upstream temperature | 26.850 °C |
| Upstream pressure (absolute) | 70.000 bar |
| Downstream pressure (absolute) | 10.000 bar |
| Critical temperature | -82.590 °C |
| Critical pressure | 45.990 bar |
| Acentric factor | 0.011400 - |
| Ideal-gas heat capacity (J/(mol·K)) | 35.700 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Downstream temperature | -2.3657 °C |
| Temperature change | -29.216 K |
| Mean Joule–Thomson coefficient (K/bar) | 0.48693 |
Open this example in the calculator and change any input.
Formula
\(h(T_1, p_1) = h(T_2, p_2), \quad h - h^{ig} = RT(Z - 1) + \frac{T\,da/dT - a}{2\sqrt2b}\ln\frac{Z + (1 + \sqrt2)B}{Z + (1 - \sqrt2)B}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_1\) | Upstream temperature | K |
| \(p_1\) | Upstream pressure | Pa |
| \(p_2\) | Downstream pressure | Pa |
| \(T_c\) | Critical temperature | K |
| \(p_c\) | Critical pressure | Pa |
| \(\omega\) | Acentric factor | - |
| \(C_p^\circ\) | Ideal-gas heat capacity (J/(mol·K)) | - |
| \(T_2\) | Downstream temperature | K |
| \(\Delta T\) | Temperature change | K |
| \(\mu_{JT}\) | Mean Joule–Thomson coefficient (K/bar) | - |
Method and standards
Peng–Robinson departure function.
Where it is used
- Gas pressure-reducing stations.
- Relief and vent temperature checks.
Common mistakes
- Ignoring condensation.
- Using C_p at another temperature.
Assumptions and limits
- Pure gas; vapour root; constant C_p°, per mole in J/(mol·K). Pressures are absolute.
- The vapour root is taken from the analytic solution of the cubic. The calculation stops if the downstream temperature falls outside 0.3–1.2 times the upstream temperature, if the enthalpy balance does not close, or if the liquid is the stable phase downstream (condensation).
References
- Isenthalpic expansion with Peng–Robinson enthalpy departure (Perry's Chemical Engineers' Handbook, 9th ed. (McGraw-Hill, 2019), sec. 2 and 4)
Questions and answers
Why does gas cool on throttling?
Molecules attract each other; expanding them apart takes energy from the gas itself, at constant enthalpy.
Why does this matter?
At gas pressure-reducing stations the cooling can form hydrates or freeze the valve; gas is often preheated.
What do the defaults represent?
Methane let down from 70 to 10 bar at 27 °C.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.