FireCADCalc

Falling-Ball Viscometer: Viscosity by Stokes' Law

Dynamic viscosity of a liquid from the terminal fall time of a ball over a distance by Stokes' law, with the Faxén wall correction and a Reynolds number check.

Inputs

Examples: Illustrative steel ball in glycerolGlass ball in castor oilSmall ball in honey, narrow tube

Accepted: 0.1 to 50 mm
Accepted: 500 to 25,000 kg/m³
Accepted: 500 to 3,000 kg/m³
Accepted: 10 to 2,000 mm
Accepted: 0.01 to 100,000 s
Accepted: 5 to 1,000 mm

Results

At terminal velocity, drag 3πμdv balances buoyant weight (π/6)d³(ρ_s − ρ_f)g, so μ = d²(ρ_s − ρ_f)g/(18v). The tube wall slows the ball; the Faxén factor f_w = 1 − 2.104(d/D) + 2.09(d/D)³ − 0.95(d/D)⁵ (for d/D up to about 0.3) corrects the result. Stokes' law requires Re below about 0.1; time the ball only after it has reached terminal speed, away from the ends.

Measured fall velocity1.1765mm/s
Viscosity, Stokes (no wall correction)6.6477Pa·s
Faxén wall factor0.74105
Viscosity with wall correction4.9263Pa·s
Ball Reynolds number5.0868e-04

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative steel ball in glycerol. The inputs, in the units selected above:

InputValue
Ball diameter2.0000 mm
Ball density7,800.0 kg/m³
Liquid density1,260.0 kg/m³
Timed fall distance200.00 mm
Fall time14.000 s
Tube inside diameter50.000 mm

Applying the formula below gives:

ResultValue
Measured fall velocity14.286 mm/s
Viscosity, Stokes (no wall correction)0.99766 Pa·s
Faxén wall factor0.91597
Viscosity with wall correction0.91383 Pa·s
Ball Reynolds number0.039394

Open this example in the calculator and change any input.

Formula

\(\mu = \frac{d^2(\rho_s - \rho_f)g}{18v}f_w, \quad f_w = 1 - 2.104\frac dD + 2.09\left(\frac dD\right)^3 - 0.95\left(\frac dD\right)^5\)

Variables

Symbol Meaning SI unit
\(d\) Ball diameter m
\(\rho_s\) Ball density kg/m³
\(\rho_f\) Liquid density kg/m³
\(L\) Timed fall distance m
\(t\) Fall time s
\(D_t\) Tube inside diameter m
\(v\) Measured fall velocity m/s
\(\mu_S\) Viscosity, Stokes (no wall correction) Pa·s
\(f_w\) Faxén wall factor -
\(\mu\) Viscosity with wall correction Pa·s
\(Re\) Ball Reynolds number -

Method and standards

Falling ball.

Where it is used

  • Viscosity of oils, syrups and polymers.
  • Teaching Stokes' law.

Common mistakes

  • Timing before terminal velocity.
  • Large balls in narrow tubes.

Assumptions and limits

  • Newtonian liquid; Re < 0.1; ball on the tube axis.

References

  • Stokes' law with Faxén's wall correction

Questions and answers

Why does the tube size matter?

The wall adds drag, slowing the ball; without correction the viscosity reads high.

What if the Reynolds number is too high?

Stokes' law no longer holds: use a smaller or lighter ball, or a more viscous range instrument.

What do the defaults represent?

An illustrative 2 mm steel ball falling 200 mm in 14 s through glycerol (1,260 kg/m³) in a 50 mm tube.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Happel and Brenner, Low Reynolds Number Hydrodynamics (Prentice-Hall, 1965), Bird, Stewart and Lightfoot, Transport Phenomena, 2nd ed. (Wiley, 2002)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.