Worked example
Example: Illustrative steel ball in glycerol. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Ball diameter | 2.0000 mm |
| Ball density | 7,800.0 kg/m³ |
| Liquid density | 1,260.0 kg/m³ |
| Timed fall distance | 200.00 mm |
| Fall time | 14.000 s |
| Tube inside diameter | 50.000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Measured fall velocity | 14.286 mm/s |
| Viscosity, Stokes (no wall correction) | 0.99766 Pa·s |
| Faxén wall factor | 0.91597 |
| Viscosity with wall correction | 0.91383 Pa·s |
| Ball Reynolds number | 0.039394 |
Open this example in the calculator and change any input.
Formula
\(\mu = \frac{d^2(\rho_s - \rho_f)g}{18v}f_w, \quad f_w = 1 - 2.104\frac dD + 2.09\left(\frac dD\right)^3 - 0.95\left(\frac dD\right)^5\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d\) | Ball diameter | m |
| \(\rho_s\) | Ball density | kg/m³ |
| \(\rho_f\) | Liquid density | kg/m³ |
| \(L\) | Timed fall distance | m |
| \(t\) | Fall time | s |
| \(D_t\) | Tube inside diameter | m |
| \(v\) | Measured fall velocity | m/s |
| \(\mu_S\) | Viscosity, Stokes (no wall correction) | Pa·s |
| \(f_w\) | Faxén wall factor | - |
| \(\mu\) | Viscosity with wall correction | Pa·s |
| \(Re\) | Ball Reynolds number | - |
Method and standards
Falling ball.
Where it is used
- Viscosity of oils, syrups and polymers.
- Teaching Stokes' law.
Common mistakes
- Timing before terminal velocity.
- Large balls in narrow tubes.
Assumptions and limits
- Newtonian liquid; Re < 0.1; ball on the tube axis.
References
- Stokes' law with Faxén's wall correction
Questions and answers
Why does the tube size matter?
The wall adds drag, slowing the ball; without correction the viscosity reads high.
What if the Reynolds number is too high?
Stokes' law no longer holds: use a smaller or lighter ball, or a more viscous range instrument.
What do the defaults represent?
An illustrative 2 mm steel ball falling 200 mm in 14 s through glycerol (1,260 kg/m³) in a 50 mm tube.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Happel and Brenner, Low Reynolds Number Hydrodynamics (Prentice-Hall, 1965), Bird, Stewart and Lightfoot, Transport Phenomena, 2nd ed. (Wiley, 2002)