Worked example
Example: 5 t from 35 °C, pre-cooled to 20, to 4 °C in 3 h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Milk | 5,000.0 kg |
| Milk specific heat | 3.9300 kJ/(kg·K) |
| Milk in | 35.000 °C |
| Milk after pre-cooling | 20.000 °C |
| Storage temperature | 4.0000 °C |
| Cooling time | 3.0000 h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat removed by pre-cooling | 81.875 kWh |
| Heat removed by refrigeration | 87.333 kWh |
| Refrigeration capacity for the milk alone (average) | 29.111 kW |
Open this example in the calculator and change any input.
Formula
\(Q_{pc} = Mc_p(T_1 - T_{pc}), \quad Q_r = Mc_p(T_{pc} - T_2), \quad \dot Q_r = \frac{Q_r}{t}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(M\) | Milk | kg |
| \(c_p\) | Milk specific heat | J/(kg·K) |
| \(T_1\) | Milk in | K |
| \(T_{pc}\) | Milk after pre-cooling | K |
| \(T_2\) | Storage temperature | K |
| \(t\) | Cooling time | s |
| \(Q_{pc}\) | Heat removed by pre-cooling | J |
| \(Q_r\) | Heat removed by refrigeration | J |
| \(\dot Q_r\) | Refrigeration capacity | W |
Method and standards
Sensible heat balance.
Where it is used
- Chilling centres and farm tanks.
Common mistakes
- Ignoring pre-cooling.
- Using kW for kWh.
Assumptions and limits
- Uniform cooling of one batch. The capacity is the average product load: tank and agitator gains and a margin are extra. Bulk tanks filled over several milkings, where warm milk is added to cold (blend temperature limits), are not modelled.
References
- Mass and energy balances (definitions)
Questions and answers
How fast must milk be cooled?
Usually to 4 °C within 2–3 hours of milking; check local rules.
Why pre-cool with water?
Well water takes milk from 35 °C to about 20 °C at almost no cost, halving the refrigeration.
Is the compressor capacity the same as the load?
Add tank and agitator gains and a margin.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.