FireCADCalc

HTST Holding Tube Length

Holding tube length for a minimum hold time from flow, bore and the ratio of fastest to mean velocity (2 laminar and transitional, about 1.2 fully turbulent), with Reynolds number.

Food, dairy and textile

Inputs

Examples: 20 m3/h milk, DN65, 15 sViscous mix laminar

Results

Regulations require the fastest particle to be held; laminar flow halves the effective tube length.

Mean velocity0.45481m/s
Reynolds number448.14
Fastest-particle factor used2.0000
Holding tube length27.289m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 20 m3/h milk, DN65, 15 s. The inputs, in the units selected above:

InputValue
Flow20.000 m³/h
Tube inner diameter60.500 mm
Minimum holding time15.000 s
Product density1,020.0 kg/m³
Product viscosity0.50000 cP

Applying the formula below gives:

ResultValue
Mean velocity1.9325 m/s
Reynolds number238,513
Fastest-particle factor used1.2000
Holding tube length34.786 m

Open this example in the calculator and change any input.

Formula

\(\bar v = \frac{4\dot V}{\pi d^2}, \quad L = k\,\bar v\,t, \quad k = 2\ (Re < 10\,000),\ 1.2\ (Re \ge 10\,000)\)

Variables

Symbol Meaning SI unit
\(\dot V\) Flow m³/s
\(d\) Tube inner diameter m
\(t\) Minimum holding time s
\(\rho\) Product density kg/m³
\(\mu\) Product viscosity Pa·s
\(\bar v\) Mean velocity m/s
\(Re\) Reynolds number -
\(v_{max}/\bar v\) Fastest-particle factor used -
\(L\) Holding tube length m

Method and standards

Residence time of the fastest particle.

Where it is used

  • Pasteuriser and UHT holding tube design.

Common mistakes

  • Using the mean velocity.
  • Ignoring viscosity of creams and mixes.

Assumptions and limits

  • Newtonian product; isothermal tube. For non-Newtonian products (cream, purées) the fastest-particle ratio differs from 2 and 1.2; the viscosity input does not make the calculation valid for them, so use the ratio from a validated study.

References

  • Mass and energy balances (definitions): fastest-particle velocity 2 × mean in laminar flow (Poiseuille) and about 1.2 × mean in turbulent flow

Questions and answers

Why the factor 2?

In laminar flow the centre-line velocity is twice the mean, so the fastest particle spends half the mean time.

What hold is needed for milk?

At least 15 s at 72 °C (HTST); check your local regulations.

Should the tube slope?

Yes, upward, so it stays full and air is purged.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.