FireCADCalc

Sterilisation Value F₀ and Equivalent Time

Lethality F₀ (minutes at 121.1 °C) of a hold at temperature T for a z-value, and the time at T to reach a target F₀ (thermal process definition).

Food, dairy and textile

Inputs

Examples: 121 °C for 5 min115 °C for 30 min, target 6

Results

Low-acid canned foods need F₀ ≥ 3 min (12 log reductions of C. botulinum); commercial processes often target 6–15. This is a screening figure for a constant temperature: a real process is set by a process authority from the measured cold-spot curve.

Lethal rate0.24547
Lethality delivered7.3641min
Time at T for the target24.443min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 121 °C for 5 min. The inputs, in the units selected above:

InputValue
Process temperature121.00 °C
Time at temperature5.0000 min
z-value10.000 K
Reference temperature121.10 °C
Target F-value3.0000 min

Applying the formula below gives:

ResultValue
Lethal rate0.97724
Lethality delivered4.8862 min
Time at T for the target3.0699 min

Open this example in the calculator and change any input.

Formula

\(L = 10^{(T - T_{ref})/z}, \quad F = L\,t, \quad t^* = \frac{F^*}{L}\)

Variables

Symbol Meaning SI unit
\(T\) Process temperature K
\(t\) Time at temperature s
\(z\) z-value K
\(T_{ref}\) Reference temperature K
\(F^*\) Target F-value s
\(L\) Lethal rate -
\(F\) Lethality delivered s
\(t^*\) Time at T for the target s

Method and standards

Thermal process lethality definition.

Where it is used

  • Retort and aseptic process checks.

Common mistakes

  • Using the retort temperature for the cold spot.
  • Mixing z-values of different organisms.

Assumptions and limits

  • Constant temperature at the cold spot. A real retort process needs the general method, summing L Δt over the measured cold-spot heating and cooling curve.
  • The F₀ ≥ 3 min figure is a regulatory minimum quoted for orientation; this calculator is a screening tool, not a process establishment.

References

  • Thermal process lethality: L = 10^((T − T_ref)/z)
  • F = Σ L Δt; F₀ for z = 10 °C and T_ref = 121.1 °C

Questions and answers

What is F₀?

The minutes at 121.1 °C (250 °F) with z = 10 °C that would give the same lethality.

Why does 1 °C matter so much?

With z = 10 °C each degree changes the lethal rate by 26 %.

Is this the whole process?

Only for a constant temperature; for heating and cooling, sum L Δt over the curve.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.