Worked example
Example: D121 = 0.2 min spores at 116 °C, 20 min. The inputs, in the units selected above:
| Input | Value |
|---|---|
| D-value at the reference temperature | 0.20000 min |
| Reference temperature | 121.10 °C |
| z-value | 10.000 K |
| Process temperature | 116.00 °C |
| Time at temperature | 20.000 min |
| Initial count (per unit) | 100,000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| D-value at T | 0.64719 min |
| Log reductions | 30.903 |
| Survivors per unit (below 1: chance of a survivor) | 1.2504e-26 |
Open this example in the calculator and change any input.
Formula
\(D_T = D_{ref}\,10^{(T_{ref} - T)/z}, \quad \log\frac{N_0}{N} = \frac{t}{D_T}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D_{ref}\) | D-value at the reference temperature | s |
| \(T_{ref}\) | Reference temperature | K |
| \(z\) | z-value | K |
| \(T\) | Process temperature | K |
| \(t\) | Time at temperature | s |
| \(N_0\) | Initial count (per unit) | - |
| \(D_T\) | D-value at T | s |
| \(\log(N_0/N)\) | Log reductions | - |
| \(N\) | Survivors per unit (below 1: chance of a survivor) | - |
Method and standards
First-order kinetics.
Where it is used
- Process validation.
- Pasteurisation and sterilisation design.
Common mistakes
- Using D at the wrong temperature.
- Extrapolating z far from data.
Assumptions and limits
- Log-linear survivor curves.
- A survivor count below 1 per unit is the probability that a unit still holds a surviving organism (for example 10⁻⁶ is one unit in a million).
References
- First-order microbial death: N = N₀·10^(−t/D); D_T = D_ref·10^((T_ref − T)/z)
Questions and answers
What is a D-value?
The time to kill 90 % of the population at a given temperature.
Why first-order?
Thermal death of a uniform population is close to exponential in time.
What is a 12-D process?
A process giving 12 log reductions of C. botulinum spores.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.