FireCADCalc

Microbial D-Value, z-Value and Log Reduction

Decimal reduction time at a process temperature from a reference D and z-value, the log reductions in a given time, and the survivors from an initial count.

Food, dairy and textile

Inputs

Examples: D121 = 0.2 min spores at 116 °C, 20 minListeria D72 0.03 s at 72 °C, 15 s

Results

Fewer than one survivor per unit: N is the probability that a unit still holds a survivor (about 1 in 8E+25).

D-value at T0.64719min
Log reductions30.903
Survivors per unit (below 1: chance of a survivor)1.2504e-26

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: D121 = 0.2 min spores at 116 °C, 20 min. The inputs, in the units selected above:

InputValue
D-value at the reference temperature0.20000 min
Reference temperature121.10 °C
z-value10.000 K
Process temperature116.00 °C
Time at temperature20.000 min
Initial count (per unit)100,000 -

Applying the formula below gives:

ResultValue
D-value at T0.64719 min
Log reductions30.903
Survivors per unit (below 1: chance of a survivor)1.2504e-26

Open this example in the calculator and change any input.

Formula

\(D_T = D_{ref}\,10^{(T_{ref} - T)/z}, \quad \log\frac{N_0}{N} = \frac{t}{D_T}\)

Variables

Symbol Meaning SI unit
\(D_{ref}\) D-value at the reference temperature s
\(T_{ref}\) Reference temperature K
\(z\) z-value K
\(T\) Process temperature K
\(t\) Time at temperature s
\(N_0\) Initial count (per unit) -
\(D_T\) D-value at T s
\(\log(N_0/N)\) Log reductions -
\(N\) Survivors per unit (below 1: chance of a survivor) -

Method and standards

First-order kinetics.

Where it is used

  • Process validation.
  • Pasteurisation and sterilisation design.

Common mistakes

  • Using D at the wrong temperature.
  • Extrapolating z far from data.

Assumptions and limits

  • Log-linear survivor curves.
  • A survivor count below 1 per unit is the probability that a unit still holds a surviving organism (for example 10⁻⁶ is one unit in a million).

References

  • First-order microbial death: N = N₀·10^(−t/D); D_T = D_ref·10^((T_ref − T)/z)

Questions and answers

What is a D-value?

The time to kill 90 % of the population at a given temperature.

Why first-order?

Thermal death of a uniform population is close to exponential in time.

What is a 12-D process?

A process giving 12 log reductions of C. botulinum spores.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.