FireCADCalc

Brewhouse Extract and Yield

Extract in the cast-out wort from volume, °Plato and specific gravity, and the brewhouse yield against the malt's laboratory extract (as-is basis).

Distillery and ethanolFood, dairy and textile

Inputs

Examples: 10 t malt, 60 m3 at 12 °PHigh gravity 16 °P

Results

Good brewhouses recover 97–99 % of laboratory extract; mash filters reach the top of the range.

Efficiency above 100 % of the laboratory extract: check the wort volume, gravity and malt mass.

Extract in the wort6,535.9kg
Brewhouse yield (extract on malt)81.698%
Brewhouse efficiency (vs laboratory extract)102.12%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 t malt, 60 m3 at 12 °P. The inputs, in the units selected above:

InputValue
Malt (grist) mashed10,000 kg
Laboratory extract of the malt (as is)78.000 %
Hot wort volume cast out60.000 m³
Wort strength (°Plato = % extract by mass)12.000 %
Specific gravity of the wort (20/20 °C)1.0484 -
Hot-to-cold volume factor0.96000 -

Applying the formula below gives:

ResultValue
Extract in the wort7,233.5 kg
Brewhouse yield (extract on malt)72.335 %
Brewhouse efficiency (vs laboratory extract)92.737 %

Open this example in the calculator and change any input.

Formula

\(E = Vk_h\cdot SG\cdot\rho_w\cdot°P, \quad Y_{BH} = \frac{E}{M_m}, \quad \eta = \frac{E}{M_mE_L}\)

Variables

Symbol Meaning SI unit
\(M_m\) Malt (grist) mashed kg
\(E_L\) Laboratory extract of the malt (as is) -
\(V\) Hot wort volume cast out m³
\(°P\) Wort strength (°Plato = % extract by mass) -
\(SG\) Specific gravity of the wort (20/20 °C) -
\(k_h\) Hot-to-cold volume factor -
\(E\) Extract in the wort kg
\(Y_{BH}\) Brewhouse yield (extract on malt) -
\(\eta\) Brewhouse efficiency (vs laboratory extract) -

Method and standards

Extract balance.

Where it is used

  • Brewhouse performance tracking.

Common mistakes

  • Using hot volume with cold gravity.
  • Mixing as-is and dry lab extract.

Assumptions and limits

  • SG measured at 20 °C. °Plato and SG fix each other; a note appears when they disagree by more than 0.002 in SG (common Plato–SG relation), and when the efficiency exceeds 100 %.

References

  • Definitions and mass and energy balances: °Plato is extract as % by mass; water density 998.2 kg/m³ at 20 °C

Questions and answers

Why convert hot to cold volume?

Wort shrinks about 4 % from near 100 °C to 20 °C; gravity is measured cold.

What is laboratory extract?

The extract the malt gives in a standard laboratory mash, the brewhouse's target.

What is °Plato?

Grams of extract per 100 g of wort.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.