FireCADCalc

Rotary Dryer Drive Power

Shaft power to turn a flighted rotary dryer from its speed, diameter, material load and total rotating load, by the Raymond (Combustion Engineering) formula.

Inputs

Examples: Illustrative 1.8 m dryer at 4 rpmLarge 3 m dryerSmall cooler

Accepted: 0.47746 to 95.493 rpm
Accepted: 0.3 to 6 m
Accepted: 1 to 1,000,000 kg
Accepted: 10 to 5,000,000 kg
Accepted: 50 to 100 %

Results

The empirical formula bhp = N(4.75 D w + 0.1925 D′ W + 0.33 W)/100 000, with N in rpm, D in ft, w and W in lb and the riding-ring diameter D′ taken as D + 2 ft, covers lifting the material by the flights, rolling friction on the tyres and trunnion friction. Inputs are SI and converted. Add the fan power separately, and size the motor for starting a fully loaded dryer.

Shaft power43.114kW
Brake horsepower57.817
Motor power50.723kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1.8 m dryer at 4 rpm. The inputs, in the units selected above:

InputValue
Rotational speed4.0000 rpm
Shell diameter1.8000 m
Material load in the dryer3,000.0 kg
Total rotating load (shell, flights, tyres and material)30,000 kg
Drive efficiency85.000 %

Applying the formula below gives:

ResultValue
Shaft power9.1871 kW
Brake horsepower12.320
Motor power10.808 kW

Open this example in the calculator and change any input.

Formula

\(bhp = \frac{N\left(4.75Dw + 0.1925D'W + 0.33W\right)}{100\,000}, \quad D' = D + 2\ \text{ft}\)

Variables

Symbol Meaning SI unit
\(N\) Rotational speed rad/s
\(D\) Shell diameter m
\(w\) Material load in the dryer kg
\(W\) Total rotating load (shell, flights, tyres and material) kg
\(\eta\) Drive efficiency -
\(P\) Shaft power W
\(bhp\) Brake horsepower -
\(P_m\) Motor power W

Method and standards

Drive power.

Where it is used

  • Sizing rotary dryer and cooler drives.
  • Checking motor loading.

Common mistakes

  • Leaving the material out of the total rotating load.
  • Using metres directly in the formula.

Assumptions and limits

  • Empirical; US units converted from SI.

References

  • Rotary dryer drive power formula (Raymond Division, Combustion Engineering)

Questions and answers

How much power does a rotary dryer need?

The defaults, a 1.8 m dryer at 4 rpm with 30 t rotating, give about 9 kW at the shaft.

Is the fan included?

No, only the drive.

What do the defaults represent?

An illustrative 1.8 m dryer at 4 rpm with 3 t of material and 30 t total rotating load.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.