Worked example
Example: Illustrative 1.8 m dryer at 4 rpm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Rotational speed | 4.0000 rpm |
| Shell diameter | 1.8000 m |
| Material load in the dryer | 3,000.0 kg |
| Total rotating load (shell, flights, tyres and material) | 30,000 kg |
| Drive efficiency | 85.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Shaft power | 9.1871 kW |
| Brake horsepower | 12.320 |
| Motor power | 10.808 kW |
Open this example in the calculator and change any input.
Formula
\(bhp = \frac{N\left(4.75Dw + 0.1925D'W + 0.33W\right)}{100\,000}, \quad D' = D + 2\ \text{ft}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(N\) | Rotational speed | rad/s |
| \(D\) | Shell diameter | m |
| \(w\) | Material load in the dryer | kg |
| \(W\) | Total rotating load (shell, flights, tyres and material) | kg |
| \(\eta\) | Drive efficiency | - |
| \(P\) | Shaft power | W |
| \(bhp\) | Brake horsepower | - |
| \(P_m\) | Motor power | W |
Method and standards
Drive power.
Where it is used
- Sizing rotary dryer and cooler drives.
- Checking motor loading.
Common mistakes
- Leaving the material out of the total rotating load.
- Using metres directly in the formula.
Assumptions and limits
- Empirical; US units converted from SI.
References
- Rotary dryer drive power formula (Raymond Division, Combustion Engineering)
Questions and answers
How much power does a rotary dryer need?
The defaults, a 1.8 m dryer at 4 rpm with 30 t rotating, give about 9 kW at the shaft.
Is the fan included?
No, only the drive.
What do the defaults represent?
An illustrative 1.8 m dryer at 4 rpm with 3 t of material and 30 t total rotating load.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)