FireCADCalc

Grain Bin Dryer: Water to Remove, Air Flow and Drying Time

Water to remove from a batch of grain, the air flow and its humidity pick-up from the air conditions, and the drying time and heat for a bin or batch dryer.

Food, dairy and textileIAPWS-IF97 (water and steam)

Inputs

Examples: Illustrative 20 t paddy batchMaize bin, low heatSeed batch, warm air

Accepted: 10 to 10,000,000 kg
Accepted: 10 to 50 %
Accepted: 5 to 40 %
Accepted: 0.006 to 60 m³/min
Accepted: -10 to 50 °C
Accepted: 0 to 100 %
Accepted: -10 to 100 °C
Accepted: -10 to 100 °C
Accepted: 0.8 to 1.1 bar

Results

A balance on the grain's dry matter gives the water to remove. Air from the fan, warmed a little, cools along a constant-enthalpy line as it picks up water from the grain; the humidity rise times the air flow is the drying rate, assuming the air leaves at the stated temperature (in practice it leaves near equilibrium with the grain, so drying slows as the grain dries). The estimate suits batch and in-bin drying with modest heat; deep beds dry as a moving front and need more air than this average suggests.

Water to remove393.26kg
Dry air flow1,959.2kg/h
Humidity pick-up4.0425g/kg
Drying time49.654h
Heater duty7.3284kW
Heat for the batch per kg of water3,331.1kJ/kg
Relative humidity of air leaving62.957%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 20 t paddy batch. The inputs, in the units selected above:

InputValue
Wet grain mass20,000 kg
Initial moisture (wet basis)22.000 %
Final moisture (wet basis)14.000 %
Air flow per tonne of wet grain3.0000 m³/min
Ambient air temperature25.000 °C
Ambient relative humidity70.000 %
Air temperature after heating40.000 °C
Air temperature leaving the grain27.000 °C
Pressure1.0132 bar

Applying the formula below gives:

ResultValue
Water to remove1,860.5 kg
Dry air flow3,969.1 kg/h
Humidity pick-up5.2581 g/kg
Drying time89.145 h
Heater duty17.066 kW
Heat for the batch per kg of water2,943.7 kJ/kg
Relative humidity of air leaving84.970 %

Open this example in the calculator and change any input.

Formula

\(m_w = M\frac{w_0 - w_1}{1 - w_1}, \quad h(T_{in}, x_a) = h(T_{out}, x_o), \quad t = \frac{m_w}{\dot m_a (x_o - x_a)}\)

Variables

Symbol Meaning SI unit
\(M\) Wet grain mass kg
\(w_0\) Initial moisture (wet basis) -
\(w_1\) Final moisture (wet basis) -
\(q\) Air flow per tonne of wet grain m³/s
\(T_a\) Ambient air temperature K
\(\varphi_a\) Ambient relative humidity -
\(T_{in}\) Air temperature after heating K
\(T_{out}\) Air temperature leaving the grain K
\(p\) Pressure Pa
\(m_w\) Water to remove kg
\(\dot m_a\) Dry air flow kg/s
\(\Delta x\) Humidity pick-up kg/kg
\(t\) Drying time s
\(\dot Q\) Heater duty W
\(E\) Heat for the batch per kg of water J/kg
\(\varphi_{out}\) Relative humidity of air leaving -

Method and standards

Grain dryer.

Where it is used

  • Rice mills, seed plants and farm storage.
  • Planning harvest drying capacity.

Common mistakes

  • Overheating seed or paddy (cracking).
  • Ignoring that drying slows as grain approaches equilibrium.

Assumptions and limits

  • Average air outlet state over the batch; adiabatic bin.

References

  • Psychrometrics: humidity ratio 0.621945 p_v/(p − p_v)
  • humid enthalpy 1006 t + x(2 501 000 + 1860 t)
  • saturation pressure from IAPWS-IF97

Questions and answers

How much water is removed from 20 t of paddy from 22 % to 14 %?

About 1,860 kg.

How much air does grain drying need?

Batch and bin dryers use about 1–10 m³/min per tonne; more air dries faster but costs fan power.

What do the defaults represent?

An illustrative 20 t batch of paddy dried from 22 % to 14 % with 3 m³/min per tonne of air at 25 °C and 70 % RH heated to 40 °C, leaving at 27 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)

Related calculators