Worked example
Example: Illustrative 20 t paddy batch. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wet grain mass | 20,000 kg |
| Initial moisture (wet basis) | 22.000 % |
| Final moisture (wet basis) | 14.000 % |
| Air flow per tonne of wet grain | 3.0000 m³/min |
| Ambient air temperature | 25.000 °C |
| Ambient relative humidity | 70.000 % |
| Air temperature after heating | 40.000 °C |
| Air temperature leaving the grain | 27.000 °C |
| Pressure | 1.0132 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water to remove | 1,860.5 kg |
| Dry air flow | 3,969.1 kg/h |
| Humidity pick-up | 5.2581 g/kg |
| Drying time | 89.145 h |
| Heater duty | 17.066 kW |
| Heat for the batch per kg of water | 2,943.7 kJ/kg |
| Relative humidity of air leaving | 84.970 % |
Open this example in the calculator and change any input.
Formula
\(m_w = M\frac{w_0 - w_1}{1 - w_1}, \quad h(T_{in}, x_a) = h(T_{out}, x_o), \quad t = \frac{m_w}{\dot m_a (x_o - x_a)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(M\) | Wet grain mass | kg |
| \(w_0\) | Initial moisture (wet basis) | - |
| \(w_1\) | Final moisture (wet basis) | - |
| \(q\) | Air flow per tonne of wet grain | m³/s |
| \(T_a\) | Ambient air temperature | K |
| \(\varphi_a\) | Ambient relative humidity | - |
| \(T_{in}\) | Air temperature after heating | K |
| \(T_{out}\) | Air temperature leaving the grain | K |
| \(p\) | Pressure | Pa |
| \(m_w\) | Water to remove | kg |
| \(\dot m_a\) | Dry air flow | kg/s |
| \(\Delta x\) | Humidity pick-up | kg/kg |
| \(t\) | Drying time | s |
| \(\dot Q\) | Heater duty | W |
| \(E\) | Heat for the batch per kg of water | J/kg |
| \(\varphi_{out}\) | Relative humidity of air leaving | - |
Method and standards
Grain dryer.
Where it is used
- Rice mills, seed plants and farm storage.
- Planning harvest drying capacity.
Common mistakes
- Overheating seed or paddy (cracking).
- Ignoring that drying slows as grain approaches equilibrium.
Assumptions and limits
- Average air outlet state over the batch; adiabatic bin.
References
- Psychrometrics: humidity ratio 0.621945 p_v/(p − p_v)
- humid enthalpy 1006 t + x(2 501 000 + 1860 t)
- saturation pressure from IAPWS-IF97
Questions and answers
How much water is removed from 20 t of paddy from 22 % to 14 %?
About 1,860 kg.
How much air does grain drying need?
Batch and bin dryers use about 1–10 m³/min per tonne; more air dries faster but costs fan power.
What do the defaults represent?
An illustrative 20 t batch of paddy dried from 22 % to 14 % with 3 m³/min per tonne of air at 25 °C and 70 % RH heated to 40 °C, leaving at 27 °C.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)