Terminal velocity of a particle, its velocity in the conveying gas and its residence time in a vertical flash dryer duct, with the particle Reynolds number.

Inputs

Examples: Illustrative 300 um particlesFine starchCoarse sawdust

Accepted: 1 to 10,000 µm
Accepted: 100 to 8,000 kg/m³
Accepted: 0.2 to 5 kg/m³
Accepted: 1E-6 to 0.0001 Pa·s
Accepted: 1 to 60 m/s
Accepted: 1 to 200 m

Results

Once accelerated, a particle rises at the gas velocity less its terminal (slip) velocity, found here with the Schiller–Naumann drag curve. The residence time in the duct is the length over that velocity, typically a few seconds, so flash drying suits surface moisture and small particles. The acceleration zone near the feed point, where the slip is largest, gives most of the heat transfer; this simple estimate ignores it, as well as wall friction and particle interaction.

Terminal velocity3.7607m/s
Particle Reynolds number at terminal velocity157.95
Particle velocity (gas minus terminal velocity)21.239m/s
Residence time in the duct1.8833s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 300 um particles. The inputs, in the units selected above:

InputValue
Particle diameter300.00 µm
Particle density1,300.0 kg/m³
Gas density0.75000 kg/m³
Gas viscosity2.4000e-05 Pa·s
Gas velocity in the duct20.000 m/s
Duct length25.000 m

Applying the formula below gives:

ResultValue
Terminal velocity1.4093 m/s
Particle Reynolds number at terminal velocity13.212
Particle velocity (gas minus terminal velocity)18.591 m/s
Residence time in the duct1.3448 s

Open this example in the calculator and change any input.

Formula

\(u_t = \sqrt{\frac{4(\rho_p - \rho_g)g d_p}{3C_D\rho_g}}, \quad C_D = \frac{24}{Re}\left(1 + 0.15Re^{0.687}\right), \quad \tau = \frac{L}{u_g - u_t}\)

Variables

Symbol Meaning SI unit
\(d_p\) Particle diameter m
\(\rho_p\) Particle density kg/m³
\(\rho_g\) Gas density kg/m³
\(\mu_g\) Gas viscosity Pa·s
\(u_g\) Gas velocity in the duct m/s
\(L\) Duct length m
\(u_t\) Terminal velocity m/s
\(Re_t\) Particle Reynolds number at terminal velocity -
\(u_p\) Particle velocity (gas minus terminal velocity) m/s
\(\tau\) Residence time in the duct s

Method and standards

Flash dryer.

Where it is used

  • Starch, gypsum, sawdust, polymers and filter cakes.
  • Choosing duct length and gas velocity.

Common mistakes

  • Ignoring the acceleration zone.
  • Using Stokes' law at high Reynolds number.

Assumptions and limits

  • Spherical particles; steady upward flow; no wall effects.

References

  • Particle slip in vertical pneumatic transport with Schiller–Naumann drag

Questions and answers

How long are particles in a flash dryer?

Usually 1–5 s; the defaults give about 1.3 s in a 25 m duct.

Why not just slow the gas down?

Below a minimum velocity the particles stop being carried and the duct chokes.

What do the defaults represent?

Illustrative 300 µm particles of density 1,300 kg/m³ in hot gas at 20 m/s up a 25 m duct.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.