FireCADCalc

Dryer Air Flow and Heat from Measured Exhaust Humidity

Dry air flow, heater duty and heat per kg of water of a hot-air dryer from the evaporation rate and measured ambient, inlet and exhaust air conditions.

Chemical and fertiliserFood, dairy and textileIAPWS-IF97 (water and steam)

Inputs

Examples: Illustrative dryer auditTextile stenter exhaustLow-temperature food dryer

Accepted: 0.036 to 180,000 kg/h
Accepted: -10 to 50 °C
Accepted: 0 to 100 %
Accepted: 30 to 500 °C
Accepted: 20 to 200 °C
Accepted: 1 to 100 %
Accepted: 0.8 to 1.1 bar

Results

Measuring the exhaust temperature and humidity tells how much water each kg of air carries away, so the evaporation rate fixes the air flow. The heater duty is that air flow times its enthalpy rise. If the exhaust is drier than the constant-enthalpy (adiabatic) line from the inlet state predicts, the difference is heat lost from the dryer or used to warm the product; it shows as the loss share. The exhaust dew point warns of condensation in ducts and cyclones.

Ambient humidity ratio9.8827g/kg
Exhaust humidity ratio23.520g/kg
Dry air flow3,666.3kg/h
Exhaust volume flow3,375.6m³/h
Heater duty46.947kW
Heat per kg of water3,380.2kJ/kg
Heat not accounted for by the adiabatic line (losses)-14.288%
Exhaust dew point27.585°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative dryer audit. The inputs, in the units selected above:

InputValue
Water evaporated300.00 kg/h
Ambient air temperature30.000 °C
Ambient relative humidity60.000 %
Air temperature after the heater120.00 °C
Exhaust air temperature60.000 °C
Exhaust relative humidity (measured)35.000 %
Pressure1.0132 bar

Applying the formula below gives:

ResultValue
Ambient humidity ratio16.043 g/kg
Exhaust humidity ratio46.021 g/kg
Dry air flow10,007 kg/h
Exhaust volume flow10,144 m³/h
Heater duty259.15 kW
Heat per kg of water3,109.8 kJ/kg
Heat not accounted for by the adiabatic line (losses)-26.016 %
Exhaust dew point38.950 °C

Open this example in the calculator and change any input.

Formula

\(x = 0.621945\frac{\varphi p_s}{p - \varphi p_s}, \quad \dot m_a = \frac{\dot m_w}{x_o - x_a}, \quad \dot Q = \dot m_a\left[h(T_{in}, x_a) - h(T_a, x_a)\right]\)

Variables

Symbol Meaning SI unit
\(\dot m_w\) Water evaporated kg/s
\(T_a\) Ambient air temperature K
\(\varphi_a\) Ambient relative humidity -
\(T_{in}\) Air temperature after the heater K
\(T_{out}\) Exhaust air temperature K
\(\varphi_{out}\) Exhaust relative humidity (measured) -
\(p\) Pressure Pa
\(x_a\) Ambient humidity ratio kg/kg
\(x_o\) Exhaust humidity ratio kg/kg
\(\dot m_a\) Dry air flow kg/s
\(\dot V_a\) Exhaust volume flow m³/s
\(\dot Q\) Heater duty W
\(q_w\) Heat per kg of water J/kg
\(f_L\) Heat not accounted for by the adiabatic line (losses) -
\(T_{dp}\) Exhaust dew point K

Method and standards

Air from humidity.

Where it is used

  • Dryer energy audits.
  • Commissioning and troubleshooting dryers.

Common mistakes

  • Measuring humidity in a dusty or condensing exhaust without protection.
  • Mixing wet-bulb and relative humidity readings.

Assumptions and limits

  • Steady state; humidity measured after any leaks.

References

  • Psychrometrics: humidity ratio 0.621945 p_v/(p − p_v)
  • humid enthalpy 1006 t + x(2 501 000 + 1860 t)
  • saturation pressure from IAPWS-IF97

Questions and answers

How do I find a dryer's air flow without measuring it?

From the evaporation rate and the humidity rise of the air: ṁ_a = ṁ_w/(x_out − x_in).

Why compare with the adiabatic line?

A real dryer loses heat through walls and to the product; the shortfall in exhaust humidity shows how much.

What do the defaults represent?

An illustrative dryer evaporating 300 kg/h with ambient 30 °C and 60 % RH, air heated to 120 °C, exhaust at 60 °C and 35 % RH.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.