Worked example
Example: Illustrative dryer audit. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water evaporated | 300.00 kg/h |
| Ambient air temperature | 30.000 °C |
| Ambient relative humidity | 60.000 % |
| Air temperature after the heater | 120.00 °C |
| Exhaust air temperature | 60.000 °C |
| Exhaust relative humidity (measured) | 35.000 % |
| Pressure | 1.0132 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Ambient humidity ratio | 16.043 g/kg |
| Exhaust humidity ratio | 46.021 g/kg |
| Dry air flow | 10,007 kg/h |
| Exhaust volume flow | 10,144 m³/h |
| Heater duty | 259.15 kW |
| Heat per kg of water | 3,109.8 kJ/kg |
| Heat not accounted for by the adiabatic line (losses) | -26.016 % |
| Exhaust dew point | 38.950 °C |
Open this example in the calculator and change any input.
Formula
\(x = 0.621945\frac{\varphi p_s}{p - \varphi p_s}, \quad \dot m_a = \frac{\dot m_w}{x_o - x_a}, \quad \dot Q = \dot m_a\left[h(T_{in}, x_a) - h(T_a, x_a)\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_w\) | Water evaporated | kg/s |
| \(T_a\) | Ambient air temperature | K |
| \(\varphi_a\) | Ambient relative humidity | - |
| \(T_{in}\) | Air temperature after the heater | K |
| \(T_{out}\) | Exhaust air temperature | K |
| \(\varphi_{out}\) | Exhaust relative humidity (measured) | - |
| \(p\) | Pressure | Pa |
| \(x_a\) | Ambient humidity ratio | kg/kg |
| \(x_o\) | Exhaust humidity ratio | kg/kg |
| \(\dot m_a\) | Dry air flow | kg/s |
| \(\dot V_a\) | Exhaust volume flow | m³/s |
| \(\dot Q\) | Heater duty | W |
| \(q_w\) | Heat per kg of water | J/kg |
| \(f_L\) | Heat not accounted for by the adiabatic line (losses) | - |
| \(T_{dp}\) | Exhaust dew point | K |
Method and standards
Air from humidity.
Where it is used
- Dryer energy audits.
- Commissioning and troubleshooting dryers.
Common mistakes
- Measuring humidity in a dusty or condensing exhaust without protection.
- Mixing wet-bulb and relative humidity readings.
Assumptions and limits
- Steady state; humidity measured after any leaks.
References
- Psychrometrics: humidity ratio 0.621945 p_v/(p − p_v)
- humid enthalpy 1006 t + x(2 501 000 + 1860 t)
- saturation pressure from IAPWS-IF97
Questions and answers
How do I find a dryer's air flow without measuring it?
From the evaporation rate and the humidity rise of the air: ṁ_a = ṁ_w/(x_out − x_in).
Why compare with the adiabatic line?
A real dryer loses heat through walls and to the product; the shortfall in exhaust humidity shows how much.
What do the defaults represent?
An illustrative dryer evaporating 300 kg/h with ambient 30 °C and 60 % RH, air heated to 120 °C, exhaust at 60 °C and 35 % RH.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)