FireCADCalc

False Air Ingress from Oxygen Rise Across a Section

False (leakage) air entering a kiln, preheater, duct or mill section from the oxygen measured before and after it, as a share of the gas and as a flow.

Inputs

Examples: Illustrative preheater towerRaw mill circuitSmall duct leak

Accepted: 0 to 20 %
Accepted: 0 to 20.5 %
Accepted: 3.6 to 36,000,000 Nm³/h
Accepted: 15 to 25 %

Results

Leakage air brings oxygen in but nothing burns in a preheater cyclone, duct or mill, so an oxygen balance gives the leak: V₁O₁ + V_a O_a = (V₁ + V_a)O₂, hence V_a/V₁ = (O₂ − O₁)/(O_a − O₂). Every per cent of false air cools the gas and loads the ID fan; preheater false air of more than about 10 % across the tower usually points to worn flap valves, inspection doors or expansion joints. Use dry oxygen readings taken at the same time.

False air as a share of the gas before the section12.158%
False air flow30,395Nm³/h
False air as a share of the gas after the section10.840%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative preheater tower. The inputs, in the units selected above:

InputValue
Oxygen before the section (dry)2.5000 %
Oxygen after the section (dry)4.5000 %
Gas flow before the section250,000 Nm³/h
Oxygen in the air20.950 %

Applying the formula below gives:

ResultValue
False air as a share of the gas before the section12.158 %
False air flow30,395 Nm³/h
False air as a share of the gas after the section10.840 %

Open this example in the calculator and change any input.

Formula

\(\frac{\dot V_a}{\dot V_1} = \frac{O_{2,2} - O_{2,1}}{O_{2,a} - O_{2,2}}\)

Variables

Symbol Meaning SI unit
\(O_{2,1}\) Oxygen before the section (dry) -
\(O_{2,2}\) Oxygen after the section (dry) -
\(\dot V_1\) Gas flow before the section Nm³/s
\(O_{2,a}\) Oxygen in the air -
\(f_a\) False air as a share of the gas before the section -
\(\dot V_a\) False air flow Nm³/s
\(f_{a,out}\) False air as a share of the gas after the section -

Method and standards

False air.

Where it is used

  • Kiln, preheater and mill energy audits.
  • Duct and ESP leakage checks.

Common mistakes

  • Mixing wet and dry oxygen readings.
  • Using the formula across a burner or calciner where fuel burns.

Assumptions and limits

  • No combustion in the section; dry oxygen.

References

  • Oxygen balance across a non-combusting section

Questions and answers

How do I calculate false air from O₂?

(O₂ after − O₂ before)/(20.95 − O₂ after), as a share of the gas before the section.

Does this work for boiler air heaters?

Yes, it is the same balance as the air heater leakage calculation.

What do the defaults represent?

An illustrative preheater tower with oxygen rising from 2.5 % at the kiln inlet to 4.5 % at the top, 250,000 Nm³/h of gas.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.