Worked example
Example: Duda Example 2.3: limestone and clay, Kind KS 0.92. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Target factor | Kind's lime saturation factor |
| Target value | 0.92000 - |
| SiO₂ in material 1 (lime component) | 1.4200 % |
| Al₂O₃ in material 1 (lime component) | 0.48000 % |
| Fe₂O₃ in material 1 (lime component) | 0.38000 % |
| CaO in material 1 (lime component) | 52.600 % |
| Loss on ignition of material 1 | 41.000 % |
| SiO₂ in material 2 (clay component) | 62.950 % |
| Al₂O₃ in material 2 (clay component) | 18.980 % |
| Fe₂O₃ in material 2 (clay component) | 7.3700 % |
| CaO in material 2 (clay component) | 1.4000 % |
| Loss on ignition of material 2 | 7.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Parts of material 1 per part of material 2 | 4.0539 |
| Material 1 in the raw mix | 80.213 % |
| Material 2 in the raw mix | 19.787 % |
| Silica ratio of the mix | 2.3028 |
| Alumina ratio of the mix | 2.3485 |
| Loss on ignition of the mix | 34.273 % |
| Raw mix per unit clinker (loss on ignition only) | 1.5214 |
Open this example in the calculator and change any input.
Formula
\(x = \frac{(2.8\,KS\,S_2 + 1.65A_2 + 0.35F_2) - C_2}{C_1 - (2.8\,KS\,S_1 + 1.65A_1 + 0.35F_1)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{target}\) | Target factor | - |
| \(KS\) | Target value | - |
| \(S_{1}\) | SiO₂ in material 1 (lime component) | - |
| \(A_{1}\) | Al₂O₃ in material 1 (lime component) | - |
| \(F_{1}\) | Fe₂O₃ in material 1 (lime component) | - |
| \(C_{1}\) | CaO in material 1 (lime component) | - |
| \(LOI_1\) | Loss on ignition of material 1 | - |
| \(S_{2}\) | SiO₂ in material 2 (clay component) | - |
| \(A_{2}\) | Al₂O₃ in material 2 (clay component) | - |
| \(F_{2}\) | Fe₂O₃ in material 2 (clay component) | - |
| \(C_{2}\) | CaO in material 2 (clay component) | - |
| \(LOI_2\) | Loss on ignition of material 2 | - |
| \(x\) | Parts of material 1 per part of material 2 | - |
| \(w_1\) | Material 1 in the raw mix | - |
| \(w_2\) | Material 2 in the raw mix | - |
| \(SR\) | Silica ratio of the mix | - |
| \(AR\) | Alumina ratio of the mix | - |
| \(LOI\) | Loss on ignition of the mix | - |
| \(f_k\) | Raw mix per unit clinker (loss on ignition only) | - |
Method and standards
Lime balance between two materials.
Where it is used
- Raw mix design for a new quarry.
- Adjusting kiln feed for a change in limestone quality.
Common mistakes
- Using wet analyses.
- Mixing material 1 and 2 roles.
Assumptions and limits
- Dry, ignited basis consistent for both.
References
- Duda
- Cement Data Book
- Vol. 1
- 3rd ed. (Bauverlag / Macdonald and Evans, 1985)
- sec. 2.3 and Example 2.3
Questions and answers
Why does the result use parts per part?
Duda solves for x parts of the lime component per part of clay; the percentages follow as x/(1 + x).
Can I fix the silica ratio too?
Not with two materials; add a corrective (sand, iron ore or pyrite ash) and use the three-component calculator.
What do the defaults represent?
Duda's Example 2.3: limestone (52.60 % CaO) and clay (62.95 % SiO₂) to Kind's factor 0.92 — 4.053 parts limestone, 80.20 / 19.80 %.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.