Worked example
Example: Ordinary Portland clinker. The inputs, in the units selected above:
| Input | Value |
|---|---|
| CaO | 66.000 % |
| SiO₂ | 21.500 % |
| Al₂O₃ | 5.2000 % |
| Fe₂O₃ | 3.2000 % |
| Free lime | 1.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Tricalcium silicate (alite) | 61.705 % |
| Dicalcium silicate (belite) | 15.090 % |
| Tricalcium aluminate | 8.3656 % |
| Tetracalcium aluminoferrite | 9.7376 % |
| Alumina ratio | 1.6250 |
| Aluminate and ferrite phases (flux) | 18.103 % |
Open this example in the calculator and change any input.
Formula
\(C_3S = 4.071C - 7.600S - 6.718A - 1.430F, \quad C_2S = 2.867S - 0.7544\,C_3S, \quad C_3A = 2.650A - 1.692F, \quad C_4AF = 3.043F\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C\) | CaO | - |
| \(S\) | SiO₂ | - |
| \(A\) | Al₂O₃ | - |
| \(F\) | Fe₂O₃ | - |
| \(CaO_f\) | Free lime | - |
| \(C_3S\) | Tricalcium silicate (alite) | - |
| \(C_2S\) | Dicalcium silicate (belite) | - |
| \(C_3A\) | Tricalcium aluminate | - |
| \(C_4AF\) | Tetracalcium aluminoferrite | - |
| \(A/F\) | Alumina ratio | - |
| \(C_3A + C_4AF\) | Aluminate and ferrite phases (flux) | - |
Method and standards
Bogue's calculation.
Where it is used
- Clinker quality control.
- Cement type selection (sulphate resisting, low heat).
Common mistakes
- Using total CaO with high free lime.
- Applying it below an alumina ratio of 0.64.
Assumptions and limits
- Equilibrium cooling; pure phases.
References
- Duda
- Cement Data Book
- Vol. 1
- 3rd ed. (Bauverlag / Macdonald and Evans, 1985)
- sec. 1.6 (Bogue)
Questions and answers
Why 'potential' composition?
Bogue's phases assume complete equilibrium and pure compounds; real clinker minerals hold foreign ions and the microscope often finds more alite.
What if the alumina ratio is below 0.64?
Then all alumina is in the ferrite phase, no C3A forms and a different set of equations (C4AF + C2F) applies.
What do the defaults represent?
A typical ordinary Portland clinker: 66.0 % CaO, 21.5 % SiO₂, 5.2 % Al₂O₃, 3.2 % Fe₂O₃, 1.0 % free lime.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.