FireCADCalc

Kiln Gas Bypass: Alkali Circulation and Reduction

Alkali circulation in a preheater kiln and the reduction of K2O or Na2O in clinker for a gas bypass fraction, from the volatility factors (Weber's method).

Inputs

Examples: K2O, 25 % bypass (Duda: 1.25 to 0.68 %)Na2O, 10 % bypassChloride-assisted volatility, 5 % bypass

Results

Typical factors (Duda Table 20.2): K₂O ε₁ 0.4–0.6 (0.6–0.8 with chloride), ε₂ 0.9; Na₂O ε₁ 0.25–0.4 (0.5–0.6), ε₂ 0.8. Calculate K₂O and Na₂O separately. A bypass also removes heat and dust: each per cent costs fuel.

Circulating alkali (per unit input)1.3846
Alkali reduction in clinker46.154%
Alkali in clinker with bypass0.67308%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: K2O, 25 % bypass (Duda: 1.25 to 0.68 %). The inputs, in the units selected above:

InputValue
Volatility of the raw-mix alkali60.000 %
Volatility of the circulating alkali90.000 %
Bypass (fraction of kiln gas and alkali not condensed in the preheater)25.000 %
Alkali in clinker without bypass1.2500 %

Applying the formula below gives:

ResultValue
Circulating alkali (per unit input)1.3846
Alkali reduction in clinker46.154 %
Alkali in clinker with bypass0.67308 %

Open this example in the calculator and change any input.

Formula

\(K - 1 = \frac{\varepsilon_1(1 - V)}{1 - \varepsilon_2(1 - V)}, \quad \Delta A = (K - 1)\frac{V}{1 - V}\)

Variables

Symbol Meaning SI unit
\(\varepsilon_1\) Volatility of the raw-mix alkali -
\(\varepsilon_2\) Volatility of the circulating alkali -
\(V\) Bypass (fraction of kiln gas and alkali not condensed in the preheater) -
\(A_0\) Alkali in clinker without bypass -
\(K - 1\) Circulating alkali (per unit input) -
\(\Delta A\) Alkali reduction in clinker -
\(A\) Alkali in clinker with bypass -

Method and standards

Weber's alkali balance.

Where it is used

  • Low-alkali cement production.
  • Sizing bypass systems.

Common mistakes

  • Using one factor for K₂O and Na₂O.
  • Ignoring the heat lost with the bypass gas.

Assumptions and limits

  • Alkali in fuel neglected.

References

  • Duda
  • Cement Data Book
  • Vol. 1
  • 3rd ed. (Bauverlag / Macdonald and Evans, 1985)
  • sec. 20.6.4 (Weber's method) and Table 20.2

Questions and answers

Why bypass kiln gas?

Volatile alkalis, chloride and sulphur evaporate in the burning zone and recondense in the preheater, building a cycle that causes build-ups and high-alkali clinker.

How large a bypass is needed?

It depends on the volatility; Duda shows 25 % bypass taking K₂O from 1.25 % to 0.68 %. Chloride bypasses of a few per cent are common today.

What do the defaults represent?

Duda's K₂O case: ε₁ 0.60, ε₂ 0.90, 25 % bypass, 1.25 % K₂O without bypass (0.68 % with).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.