FireCADCalc

Degree of Calcination of Hot Meal from Loss on Ignition

Apparent degree of calcination of kiln-inlet or calciner-outlet hot meal from the loss on ignition of the raw meal and of the hot meal sample.

Inputs

Examples: Illustrative 35.5 % raw meal, 6 % hot mealKiln inlet without calcinerOver-calcined calciner outlet

Accepted: 20 to 45 %
Accepted: 0 to 40 %

Results

DoC = 1 − LOI_hm(1 − LOI_rm)/[LOI_rm(1 − LOI_hm)]: LOI is referred to the ignited (loss-free) basis so that the comparison is per unit of clinker-forming solids. Calciner outlets run about 90–95 %; recirculating dust and bypass streams distort the apparent value. Ash from fuel is neglected.

Degree of calcination88.403%
Share of raw-meal CO₂ still to be released11.597%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 35.5 % raw meal, 6 % hot meal. The inputs, in the units selected above:

InputValue
Loss on ignition of raw meal35.500 %
Loss on ignition of hot meal6.0000 %

Applying the formula below gives:

ResultValue
Degree of calcination88.403 %
Share of raw-meal CO₂ still to be released11.597 %

Open this example in the calculator and change any input.

Formula

\(DoC = 1 - \frac{LOI_{hm}(1 - LOI_{rm})}{LOI_{rm}(1 - LOI_{hm})}\)

Variables

Symbol Meaning SI unit
\(LOI_{rm}\) Loss on ignition of raw meal -
\(LOI_{hm}\) Loss on ignition of hot meal -
\(DoC\) Degree of calcination -
\(\text{CO}_2\ \text{left}\) Share of raw-meal CO₂ still to be released -

Method and standards

Calcination.

Where it is used

  • Preheater and calciner performance checks.
  • Kiln inlet sampling.

Common mistakes

  • Using LOI from samples with recirculated dust or bypass material.
  • Ignoring CO₂ from carbonates other than CaCO₃.

Assumptions and limits

  • All LOI is carbonate CO₂ (moisture and organics negligible).

References

  • Loss-on-ignition calcination balance

Questions and answers

Why not just compare LOI values directly?

The hot meal has lost mass, so its LOI must be referred to the same non-volatile basis as the raw meal.

What calcination is wanted at the kiln inlet?

About 90–95 % with a calciner; higher risks build-ups in the riser.

What do the defaults represent?

An illustrative raw meal with 35.5 % LOI and hot meal at 6 % LOI.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duda, Cement Data Book, Vol. 1, 3rd ed. (Bauverlag, 1985), Alsop, Cement Plant Operations Handbook, 6th ed. (Tradeship, 2014)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.