Worked example
Example: Illustrative OPC sample. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Specific surface of the reference powder | 334.00 m²/kg |
| Flow time of the reference | 52.000 s |
| Density of the reference | 3,150.0 kg/m³ |
| Porosity of the reference bed | 50.000 % |
| Flow time of the sample | 60.000 s |
| Density of the sample | 3,150.0 kg/m³ |
| Porosity of the sample bed | 50.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Specific surface of the sample | 3,587.7 cm²/g |
| Ratio to the reference | 1.0742 |
Open this example in the calculator and change any input.
Formula
\(S = S_s\frac{\rho_s}{\rho}\sqrt{\frac{t}{t_s}}\,\frac{1 - \varepsilon_s}{1 - \varepsilon}\sqrt{\frac{\varepsilon^3}{\varepsilon_s^3}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S_s\) | Specific surface of the reference powder | m²/kg |
| \(t_s\) | Flow time of the reference | s |
| \(\rho_s\) | Density of the reference | kg/m³ |
| \(\varepsilon_s\) | Porosity of the reference bed | - |
| \(t\) | Flow time of the sample | s |
| \(\rho\) | Density of the sample | kg/m³ |
| \(\varepsilon\) | Porosity of the sample bed | - |
| \(S\) | Specific surface of the sample | m²/kg |
| \(S/S_s\) | Ratio to the reference | - |
Method and standards
Blaine method.
Where it is used
- Cement mill quality control.
- Fly ash and slag fineness.
Common mistakes
- Ignoring a change in bed porosity.
- Comparing Blaine with laser-diffraction surface.
Assumptions and limits
- Same apparatus and air temperature as the reference.
References
- Air-permeability (Blaine) method on the Carman–Kozeny relation
- calibrated with a reference powder
Questions and answers
What Blaine is normal for OPC?
About 300–400 m²/kg; rapid-hardening cements are finer.
Why must the porosity match?
The flow time depends strongly on porosity, so the bed mass is chosen to give the porosity of the method, usually 0.500 for cement.
What do the defaults represent?
A sample timed at 60 s against a reference of 334 m²/kg timed at 52 s, both at porosity 0.5 and density 3,150 kg/m³.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Duda, Cement Data Book, Vol. 1, 3rd ed. (Bauverlag, 1985)