FireCADCalc

Rotary Kiln Shell Heat Loss by Radiation and Convection

Heat lost from a rotary kiln shell from its mean surface temperature, emissivity and convective coefficient, the loss per kg of clinker and the loss per metre.

Inputs

Examples: Illustrative 4.8 x 74 m kiln at 300 CLarge 5.6 x 87 m at 280 CHot spot kiln 4 x 60 m at 380 C

Accepted: 1 to 8 m
Accepted: 10 to 250 m
Accepted: 46.85 to 476.85 °C
Accepted: -10.15 to 49.85 °C
Accepted: 50 to 100 %
Accepted: 2 to 100 W/(m²·K)
Accepted: 8.64 to 86,400 t/d

Results

Q = (h_r + h_c)A(T_s − T₀), h_r = εσ(T_s² + T₀²)(T_s + T₀). Use a shell scanner's profile in segments for accuracy, since the burning zone runs much hotter than the inlet. Shell losses are typically 100–200 kJ/kg clinker; wind and shell fans raise h_c. Coating loss shows as hot spots.

Radiation coefficient16.712W/(m²·K)
Shell area1,115.9m²
Shell heat loss8.6506MW
Loss per metre116.90kW/m
Loss per kg clinker249.14kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 4.8 x 74 m kiln at 300 C. The inputs, in the units selected above:

InputValue
Shell outside diameter4.8000 m
Kiln length74.000 m
Mean shell temperature300.00 °C
Ambient temperature30.000 °C
Shell emissivity80.000 %
Convective coefficient12.000 W/(m²·K)
Clinker production3,000.0 t/d

Applying the formula below gives:

ResultValue
Radiation coefficient16.712 W/(m²·K)
Shell area1,115.9 m²
Shell heat loss8.6506 MW
Loss per metre116.90 kW/m
Loss per kg clinker249.14 kJ/kg

Open this example in the calculator and change any input.

Formula

\(\dot Q = (h_r + h_c)\pi DL(T_s - T_0), \quad h_r = \varepsilon\sigma(T_s^2 + T_0^2)(T_s + T_0)\)

Variables

Symbol Meaning SI unit
\(D\) Shell outside diameter m
\(L\) Kiln length m
\(T_s\) Mean shell temperature K
\(T_0\) Ambient temperature K
\(\varepsilon\) Shell emissivity -
\(h_c\) Convective coefficient W/(m²·K)
\(\dot m_{cl}\) Clinker production kg/s
\(h_r\) Radiation coefficient W/(m²·K)
\(A\) Shell area m²
\(\dot Q\) Shell heat loss W
\(\dot Q/L\) Loss per metre W/m
\(q_{sp}\) Loss per kg clinker J/kg

Method and standards

Shell loss.

Where it is used

  • Kiln heat balances.
  • Judging refractory condition and insulation upgrades.

Common mistakes

  • Using burning-zone temperature for the whole shell.
  • Ignoring wind effects on convection.

Assumptions and limits

  • Uniform mean shell temperature; grey surface; no shading by tyres.

References

  • Radiation and convection from a surface

Questions and answers

How hot do kiln shells run?

About 200–350 °C normally; above 400 °C locally signals coating loss or refractory damage.

Why is the loss so large?

A big hot surface radiates heavily: at 300 °C each square metre loses several kilowatts.

What do the defaults represent?

An illustrative 4.8 m × 74 m kiln with a mean shell temperature of 300 °C, ε 0.8, h_c 12 W/(m²·K), producing 3,000 t/d.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Incropera and DeWitt, Fundamentals of Heat and Mass Transfer, 6th ed. (Wiley, 2007), Peray, The Rotary Cement Kiln, 2nd ed. (Chemical Publishing, 1986)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.