FireCADCalc

Clinker Cooler Heat Recuperation Efficiency

Heat returned to the kiln by secondary and tertiary air as a share of the heat in hot clinker entering a grate cooler, with the heat left in cooled clinker.

Inputs

Examples: Illustrative grate cooler with calcinerKiln without tertiary airOlder cooler, poor recuperation

Accepted: 999.85 to 1,499.8 °C
Accepted: 26.85 to 326.85 °C
Accepted: 0.7 to 1.2 kJ/(kg·K)
Accepted: 0.1 to 2 Nm³/kg
Accepted: 499.85 to 1,299.8 °C
Accepted: 0 to 2 Nm³/kg
Accepted: 299.85 to 1,099.8 °C
Accepted: 1.25 to 1.6
Accepted: -10.15 to 49.85 °C

Results

η = heat in secondary + tertiary air / heat in clinker entering, relative to T₀. Modern grate coolers recuperate about 70–78 %; the rest leaves in vent air (often used for coal drying or power), cooled clinker and shell losses. c_v,a in kJ/(Nm³·K) is the mean value from T₀ to the air temperature (about 1.38–1.43).

Heat in hot clinker1,449.0kJ/kg
Heat recuperated to kiln and calciner1,041.6kJ/kg
Heat leaving with clinker136.50kJ/kg
Recuperation efficiency71.884%
Remainder (vent air and losses)270.90kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative grate cooler with calciner. The inputs, in the units selected above:

InputValue
Clinker temperature into the cooler1,400.0 °C
Clinker temperature out110.00 °C
Clinker mean specific heat1.0500 kJ/(kg·K)
Secondary air per kg clinker0.35000 Nm³/kg
Secondary air temperature1,100.0 °C
Tertiary air per kg clinker0.45000 Nm³/kg
Tertiary air temperature850.00 °C
Air mean volumetric heat capacity1.4000 -
Reference temperature20.000 °C

Applying the formula below gives:

ResultValue
Heat in hot clinker1,449.0 kJ/kg
Heat recuperated to kiln and calciner1,052.1 kJ/kg
Heat leaving with clinker94.500 kJ/kg
Recuperation efficiency72.609 %
Remainder (vent air and losses)302.40 kJ/kg

Open this example in the calculator and change any input.

Formula

\(\eta_r = \frac{c_{v,a}\left[v_{sa}(T_{sa} - T_0) + v_{ta}(T_{ta} - T_0)\right]}{c_{cl}(T_{cl,in} - T_0)}\)

Variables

Symbol Meaning SI unit
\(T_{cl,in}\) Clinker temperature into the cooler K
\(T_{cl,out}\) Clinker temperature out K
\(c_{cl}\) Clinker mean specific heat J/(kg·K)
\(v_{sa}\) Secondary air per kg clinker m³/kg
\(T_{sa}\) Secondary air temperature K
\(v_{ta}\) Tertiary air per kg clinker m³/kg
\(T_{ta}\) Tertiary air temperature K
\(c_{v,a}\) Air mean volumetric heat capacity -
\(T_0\) Reference temperature K
\(q_{in}\) Heat in hot clinker J/kg
\(q_r\) Heat recuperated to kiln and calciner J/kg
\(q_{cl}\) Heat leaving with clinker J/kg
\(\eta_r\) Recuperation efficiency -
\(q_{vent}\) Remainder (vent air and losses) J/kg

Method and standards

Cooler balance.

Where it is used

  • Cooler performance tests.
  • Assessing cooler upgrades.

Common mistakes

  • Using a volumetric heat capacity at the wrong temperature.
  • Ignoring tertiary air on calciner kilns.

Assumptions and limits

  • Mean heat capacities; steady state.

References

  • Cooler heat balance

Questions and answers

Why does cooler efficiency matter so much?

Every kJ not returned as hot secondary or tertiary air must be supplied by fuel in the kiln or calciner.

What is a good recuperation efficiency?

About 70 % or more for modern grate coolers; older planetary or grate coolers may be 50–60 %.

What do the defaults represent?

Illustrative clinker entering at 1,400 °C and leaving at 110 °C, 0.35 Nm³/kg secondary air at 1,100 °C and 0.45 Nm³/kg tertiary air at 850 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duda, Cement Data Book, Vol. 1, 3rd ed. (Bauverlag, 1985), Alsop, Cement Plant Operations Handbook, 6th ed. (Tradeship, 2014)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.