Worked example
Example: Illustrative grate cooler with calciner. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Clinker temperature into the cooler | 1,400.0 °C |
| Clinker temperature out | 110.00 °C |
| Clinker mean specific heat | 1.0500 kJ/(kg·K) |
| Secondary air per kg clinker | 0.35000 Nm³/kg |
| Secondary air temperature | 1,100.0 °C |
| Tertiary air per kg clinker | 0.45000 Nm³/kg |
| Tertiary air temperature | 850.00 °C |
| Air mean volumetric heat capacity | 1.4000 - |
| Reference temperature | 20.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat in hot clinker | 1,449.0 kJ/kg |
| Heat recuperated to kiln and calciner | 1,052.1 kJ/kg |
| Heat leaving with clinker | 94.500 kJ/kg |
| Recuperation efficiency | 72.609 % |
| Remainder (vent air and losses) | 302.40 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(\eta_r = \frac{c_{v,a}\left[v_{sa}(T_{sa} - T_0) + v_{ta}(T_{ta} - T_0)\right]}{c_{cl}(T_{cl,in} - T_0)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_{cl,in}\) | Clinker temperature into the cooler | K |
| \(T_{cl,out}\) | Clinker temperature out | K |
| \(c_{cl}\) | Clinker mean specific heat | J/(kg·K) |
| \(v_{sa}\) | Secondary air per kg clinker | m³/kg |
| \(T_{sa}\) | Secondary air temperature | K |
| \(v_{ta}\) | Tertiary air per kg clinker | m³/kg |
| \(T_{ta}\) | Tertiary air temperature | K |
| \(c_{v,a}\) | Air mean volumetric heat capacity | - |
| \(T_0\) | Reference temperature | K |
| \(q_{in}\) | Heat in hot clinker | J/kg |
| \(q_r\) | Heat recuperated to kiln and calciner | J/kg |
| \(q_{cl}\) | Heat leaving with clinker | J/kg |
| \(\eta_r\) | Recuperation efficiency | - |
| \(q_{vent}\) | Remainder (vent air and losses) | J/kg |
Method and standards
Cooler balance.
Where it is used
- Cooler performance tests.
- Assessing cooler upgrades.
Common mistakes
- Using a volumetric heat capacity at the wrong temperature.
- Ignoring tertiary air on calciner kilns.
Assumptions and limits
- Mean heat capacities; steady state.
References
- Cooler heat balance
Questions and answers
Why does cooler efficiency matter so much?
Every kJ not returned as hot secondary or tertiary air must be supplied by fuel in the kiln or calciner.
What is a good recuperation efficiency?
About 70 % or more for modern grate coolers; older planetary or grate coolers may be 50–60 %.
What do the defaults represent?
Illustrative clinker entering at 1,400 °C and leaving at 110 °C, 0.35 Nm³/kg secondary air at 1,100 °C and 0.45 Nm³/kg tertiary air at 850 °C.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.