FireCADCalc

HRSG Steam Generation (Pinch and Approach)

Steam a heat recovery steam generator (HRSG) or exhaust boiler makes from gas flow and temperature, with pinch point, approach and stack temperature (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerEconomiser and air preheater

Inputs

Examples: GT exhaust 100 kg/s at 550 °C, 40 bar(a) / 400 °C, feed 105 °C, pinch 10 K, approach 5 KEngine exhaust 20 kg/s at 400 °C, 10 bar(a) saturated, feed 105 °C, pinch 15 K, approach 8 KGT 200 kg/s at 600 °C, 80 bar(a) / 500 °C, feed 140 °C, 8 K / 5 K

Results

Steam generated117,558kg/h
Stack (gas exit) temperature205.16°C
Total heat recovered91.604MW
Economiser duty22.702MW
Gas temperature at the pinch303.01°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: GT exhaust 100 kg/s at 550 °C, 40 bar(a) / 400 °C, feed 105 °C, pinch 10 K, approach 5 K. The inputs, in the units selected above:

InputValue
Exhaust gas flow360,000 kg/h
Mean specific heat of the gas1.1500 kJ/(kg·K)
Gas temperature entering550.00 °C
Steam (drum) pressure (absolute)40.000 bar
Steam conditionSuperheated at the temperature below
Superheated steam temperature400.00 °C
Feedwater temperature105.00 °C
Pinch point (gas leaving evaporator minus saturation)10.000 K
Approach (saturation minus economiser water outlet)5.0000 K

Applying the formula below gives:

ResultValue
Steam generated55,743 kg/h
Stack (gas exit) temperature176.86 °C
Total heat recovered42.911 MW
Economiser duty9.6024 MW
Gas temperature at the pinch260.36 °C

Open this example in the calculator and change any input.

Formula

\(T_{g,p} = T_{sat} + \Delta T_p \qquad \dot m_s = \frac{\dot m_g c_{p,g}(T_{g,1} - T_{g,p})}{h_s - h_{eco}},\ h_{eco} = h(p, T_{sat} - \Delta T_a)\)

\(\dot Q_{eco} = \dot m_s (h_{eco} - h_{fw}) \qquad T_{st} = T_{g,p} - \frac{\dot Q_{eco}}{\dot m_g c_{p,g}} \qquad \dot Q = \dot m_s (h_s - h_{fw})\)

Variables

Symbol Meaning SI unit
\(\dot m_g\) exhaust gas flow kg/s
\(c_{p,g}\) gas specific heat J/(kg·K)
\(T_{g,1}\) gas inlet temperature K
\(p\) drum pressure Pa
\(\text{state}\) saturated or superheated –
\(T_s\) superheated steam temperature K
\(T_{fw}\) feedwater temperature K
\(\Delta T_p\) pinch point K
\(\Delta T_a\) approach K
\(\dot m_s\) steam generated kg/s
\(T_{st}\) stack temperature K
\(\dot Q\) total heat recovered W
\(\dot Q_{eco}\) economiser duty W
\(T_{g,p}\) gas temperature at the pinch K
\(T_{sat}\) saturation temperature K
\(h_s, h_{eco}, h_{fw}\) steam, economiser outlet and feedwater enthalpies (IF97) J/kg

Method and standards

Pinch-point method as described by V. Ganapathy for HRSG performance; water and steam enthalpies from FireCAD's IAPWS-IF97; gas with a mean specific heat.

Where it is used

  • Sizing HRSGs for gas turbines and engines.
  • Estimating steam from a combined-cycle or cogeneration exhaust.
  • Checking off-design performance quickly.

Common mistakes

  • Choosing a pinch that is too small to be economic.
  • Using air specific heat for exhaust gas.
  • Forgetting blowdown (there is no blowdown input: the economiser duty here covers the steam only) and that the economiser may steam at part load.

Assumptions and limits

  • Single pressure, unfired; constant gas specific heat; no casing loss; no blowdown.
  • The stack must stay above the feedwater temperature; otherwise the case fails, because the economiser cannot absorb the duty.
  • The superheated steam must be below the gas inlet temperature. With the pinch fixed below the evaporator, the gas leaving the superheater is always above saturation, so no other profile check is needed.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q4.34 (HRSG design with pinch and approach); IAPWS R7-97 IF97

Questions and answers

How much steam can a gas turbine's exhaust make?

100 kg/s of exhaust at 550 °C making 40 bar(a) / 400 °C steam from 105 °C feedwater, with a 10 K pinch and 5 K approach, gives 15.5 kg/s (56 t/h); the gas leaves the evaporator at 260 °C and the stack at 177 °C.

What do pinch and approach mean?

Pinch is how far the gas leaving the evaporator stays above saturation; approach is how far the economiser water stays below it. Smaller values recover more heat but need much more surface.

Why fix the pinch first?

Steam generation is set by the gas cooling down to the pinch; the economiser then takes what it can from the gas below. Ganapathy's method follows this order.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.