Worked example
Example: Coal 2.5 t/h, air 5 t/h per pipe, 350 mm, 75 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pulverised coal flow per pipe | 2,500.0 kg/h |
| Primary air flow per pipe, dry | 5,000.0 kg/h |
| Pipe inside diameter | 350.00 mm |
| Mill outlet (mixture) temperature | 75.000 °C |
| Pipe pressure (absolute) | 1.0433 bar |
| Primary air humidity, kg water per kg dry air | 0.013000 kg/kg |
| Total moisture of the raw coal | 15.000 % |
| Moisture left in the pulverised coal | 2.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gas velocity in the pipe (air with its humidity and the evaporated coal moisture) | 15.817 m/s |
| Water vapour in the pipe (air humidity and coal moisture driven off) | 447.35 kg/h |
| Coal loading, kg coal per kg air | 0.50000 kg/kg |
| Air-to-coal ratio | 2.0000 kg/kg |
Open this example in the calculator and change any input.
Formula
\(\dot m_v = x_a \dot m_a + \dot m_c \frac{M_{in} - M_{out}}{1 - M_{in}}\)
\(v = \frac{\dot m_a/\rho_a(T, p) + \dot m_v/\rho_v(T, p)}{\pi D^2/4} \qquad \mu_c = \frac{\dot m_c}{\dot m_a} \qquad A/C = \frac{\dot m_a}{\dot m_c}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_c\) | pulverised coal flow per pipe | kg/s |
| \(\dot m_a\) | primary air per pipe, dry air | kg/s |
| \(D\) | pipe bore | m |
| \(T\) | mill outlet temperature | K |
| \(p\) | pipe pressure | Pa |
| \(x_a\) | primary air humidity, kg water vapour per kg dry air | kg/kg |
| \(M_{in}\) | total moisture of the raw coal | - |
| \(M_{out}\) | moisture left in the pulverised coal | - |
| \(\dot m_v\) | water vapour in the pipe | kg/s |
| \(v\) | gas velocity | m/s |
| \(\mu_c\) | coal loading | kg/kg |
| \(A/C\) | air-to-coal ratio | kg/kg |
| \(\rho_a\) | dry air density | kg/m³ |
| \(\rho_v\) | water vapour density (ideal gas) | kg/m³ |
Method and standards
The gas in the pipe is the dry primary air, the water vapour its humidity carries, and the moisture driven off the coal in the mill ((M_in − M_out)/(1 − M_in) kg per kg of pulverised coal). Each is taken at the mill outlet temperature and pipe pressure by the ideal-gas law and the volumes are added; the coal's own volume is neglected.
Where it is used
- Checking PF pipe sizing and primary air settings.
- Balancing coal flow between pipes.
- Investigating pipe fires and erosion.
Common mistakes
- Using fan inlet air density instead of mill outlet.
- Using total mill air for one pipe.
- Ignoring tempering air added after the mill.
Assumptions and limits
- Gas velocity only (slip of coal particles not modelled). The vapour from the coal and the air humidity add roughly 15 % to the dry-air velocity for 15 % moisture coal dried to 2 % at an air-to-coal ratio of 2; enter zero humidity and moisture to see the dry-air figure.
- The pipe pressure is absolute: add the atmospheric pressure to a gauge reading.
References
- Continuity with the ideal-gas law for air
Questions and answers
How fast does air carry coal in a PF pipe?
5 t/h of dry primary air at 75 °C in a 350 mm pipe, with 0.013 kg/kg humidity and the vapour from drying 15 % moisture coal to 2 %, moves at 15.8 m/s carrying 2.5 t/h of coal (0.5 kg of coal per kg of air).
Why is there a minimum velocity?
Below it coal drops out, builds up in the pipe and can catch fire; the mill and burner maker set the minimum.
Why not just run faster?
Erosion of pipes, bends and burner nozzles rises steeply with velocity, and so does primary air fan power.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.